Operating procedure photos – MITSUBISHI ELECTRIC Mitsubishi Split-Type User Manual

Page 25

Advertising
background image

25

2. Removing the electronic control P.C. board, the

power monitor receiver P.C. board, SW P.C. board
and the terminal block

(1) Remove the horizontal vane, the panel (Refer to 1.) and

the corner box.

(2) Remove the screw of V.A. clamp, and then the

indoor/outdoor connecting wire. (See Photo 2.)

(3) Remove the switch holder from the electrical cover.

(See Photo 3.)

(4) Remove the screw of the electrical cover, and then the

electrical cover. (See Photo 3.)

(5) Remove the ground wire connected to the indoor

electronic control P.C. board from the electrical box.

(See Photo 4.)

(6) Unhook the power monitor receiver P.C. board holder from

the catch. (See Photo 4.)

(7) Open the rear cover of the power monitor receiver P.C.

board holder and pull out the power monitor receiver P.C.
board.

(8) Open the switch holder and pull out SW P.C. board.
(9) Pull the electronic control P.C. board slightly toward you

from the electrical box, and disconnect TAB3 and all the
connectors on the electronic control P.C. board.
(LD101 and LD105 are direct-mounted to the electronic

control P.C. board.)

(10) Pull out the electronic control P.C. board from the electrical

box.

(11) Remove the ground wire connected to the heat exchanger

from the electrical box. (See Photo 4.)

(12) Unhook the catches of the electrical box, and pull out the

electrical box.

(13) Remove the screws of the terminal block cover, and then

the terminal block cover and the terminal block holder.
(See Photo 2.)

(14) Remove the terminal block by sliding it.

OPERATING PROCEDURE

PHOTOS

Screw of the
electrical cover.

Switch holder

Photo 3

3. Removing the electrical box

(1) Remove the horizontal vane, the panel (Refer to 1.) and

the corner box.

(2) Remove the screw of V.A. clamp, and then the indoor/

outdoor connecting wire. (See Photo 2.)

(3) Remove the switch holder and the electrical cover.

(See Photo 3.)

(4) Remove the ground wire connected to the heat exchanger

from the electrical box. (See Photo 4.)

(5) Disconnect the following connectors on the electronic

control P.C. board; the fan motor connector <CN211>, the
indoor coil thermistor connector <CN112>, the vane motor
connector <CN151>, the connector of the interlock switch
(Fan) of the horizontal vane <CN1R1>.

(6) Unhook the catches of the electrical box, and pull out the

electrical box.

Photo 4

Indoor coil thermistor
connector (CN112)

Fan motor
connector (CN211)

Vane motor
connector (CN151)

Ground wires

Photo 2

Screws of
the terminal
block cover

Screw of V.A. clamp

Power monitor
receiver P.C.
board holder

Connector of the
interlock switch(Fan)
(CN1R1)

Drain hose

OB378_--1qxp 05.1.17 12:55 Page 25