6wiring diagram refrigerant system diagram 7, Indoor unit, Indoor unit models wiring diagram – MITSUBISHI ELECTRIC Mitsubishi Split-Type User Manual

Page 8

Advertising
background image

8

6

WIRING DIAGRAM

REFRIGERANT SYSTEM DIAGRAM

7

MSZ-GA22VA -
MSZ-GA25VA -
MSZ-GA35VA -

E1

E1

E1

Indoor

heat

exchanger

Flared connection

Room temperature
thermistor
RT11

Indoor coil
thermistor
RT13(sub)

Flared connection

Refrigerant flow in cooling

Refrigerant flow in heating

Refrigerant pipe

[

9.52

(with heat insulator)

Refrigerant pipe

[

6.35

(with heat insulator)

Indoor coil
thermistor
RT12(main)

INDOOR UNIT

Unit : mm

INDOOR UNIT

MODELS WIRING DIAGRAM

SYMBOL

DB111

F11

MF

MV

NR11

SYMBOL

RT11

RT12
RT13

T111

TB

NAME

DIODE STACK
FUSE (T3.15AL250V)
INDOOR FAN MOTOR
VANE MOTOR (HORIZONTAL)
VARISTOR

NAME

ROOM TEMPERATURE THERMISTOR
INDOOR COIL THERMISTOR (MAIN)
INDOOR COIL THERMISTOR (SUB)
TRANSFORMER
TERMINAL BLOCK

NOTE:1. About the outdoor side electric wiring refer to the outdoor unit electric wiring diagram for servicing.

2. Use copper conductors only. (For field wiring)
3. Symbols below indicate.

/

: Terminal block, : Connector

MSZ-GA22VA -
MSZ-GA25VA -
MSZ-GA35VA -

E1

E1

E1

4
3
2
1

S2

POWER MONITOR
RECEIVER P.C.BOARD

2

6

230V~

BLU

INDOOR ELECTRONIC

CONTROL P.C. BOARD

SW P.C.
BOARD

INTERLOCK
SWITCH(FAN)

5

MV

TO OUTDOOR

UNIT

CONNECTING

BLK

RED

S3

TB

TAB3

DB111

NR11

F11

5

6

4

2

2

LD

105(T)

LD

101(A)

12-24V

RT13

1R1

CN

GRN

LD104

CN201

2
1

151

CN

T111

RED

WHT

111

CN

CN

112

CN211

BLU

YLW

BLK

MF

RT11

RT12

1

3

5

S1

OB378_--1qxp 05.1.17 12:55 Page 8

Advertising
This manual is related to the following products: