3. volt-ampere curves – Miller Electric XMS 4000 User Manual

Page 14

Advertising
background image

OM-224 043 Page 10

3-3. Volt-Ampere Curves

va_curve1 4/95 − SA-178 652 / SA-178 653

Volt-ampere curves show minimum

and maximum voltage and amper-

age output capabilities of unit.

Curves of other settings fall be-

tween curves shown.

A. CC Mode

B. CV Mode

ARC CONTROL

3-4. Installing Turntable for Wire Feeder on Power Source (Optional)

Y Turn off welding power

source and disconnect input

power before proceeding.

Remove wire spool.
1

Turntable

2

Screw

Remove the 4 screws and the plas-

tic cap on the power source upper

cover and keep them for future use.
Insert the turntable in the upper hole

and secure with 4 screws. Be sure

screws are tight.
If desired, install the wire feeder on

the turntable using the hole in the

bottom of the feeder.

1

2

Advertising