Section 5 − maintenance & troubleshooting, 1. routine maintenance, 3 months – Miller Electric XMS 4000 User Manual
Page 29: 6 months, 12 months
Advertising
OM-224 043 Page 25
SECTION 5 − MAINTENANCE & TROUBLESHOOTING
5-1. Routine Maintenance
Y Disconnect power
before maintaining.
.
Maintain more often
during severe conditions.
3 Months
Replace
Damaged Or
Unreadable
Labels
Replace Cracked
Torch Body
Repair Or
Replace
Cracked
Cables
Repair Or Replace
Cracked Cables
And Cords
Clean
And
Tighten Weld
Connections
6 Months
Replace
Cracked
Hoses
Blow Out Inside
Change
Coolant (If
Using Water)
Blow Out Heat
Exchanger Fins
12 Months
Change Coolant (If
Using MILLER Coolant)