7. trigger mode selection (tig and stick only) – Miller Electric XMS 4000 User Manual

Page 22

Advertising
background image

OM-224 043 Page 18

4-6. Gas Selection in Synergic MIG or Synergic Pulsed MIG Welding

L13 LED

L14 LED

L15 LED

L16 LED

P6 Push Button

Press P6 until gas LED illuminates. D1 and

D2 will show gas name momentarily and

then it will return to the main display. If it is

allowed, change gas type during this time.

.

D1 and D2 will show NO PROG or a
selection will not be allowed when

there is no program for the process,

material, wire diameter, and shielding

gas combination.

L13 (Ar 100%) selection is for 100% Argon

(generally used with aluminum and light al-

loys).
L14 (ArCO

2

[1])selection is for mixed gas

with Argon and CO

2

around 20% (general-

ly used with carbon steel).
L15 (ArCO

2

[2]) selection is for mixed gas

with Argon and CO

2

around 2% (generally

used with stainless steel).
L16 (Special) selection is for other gas type

not provided by standard selection.

L13

L14

L15

L16

P6

4-7. Trigger Mode Selection (TIG and STICK Only)

.

Always check and set a trigger mode.
If trigger mode is undefined for a weld-

ing process, select the desired mode.

L17 LED
L18 LED
L19LED
L20 LED
P7 Push Button
Trigger mode can be set for TIG only.
Trigger mode also allows enabling and dis-

abling STICK welding.
In TIG welding, pressing P6 will change the

trigger mode, but D1 and D2 will not change

values.
In STICK welding, pressing P6 will enable

welding (L20 ON, D1 shows open circuit

voltage or weld voltage and D2 shows set

current or welding current) or disable weld-

ing (L20 OFF, D1 shows STK and D2

shows set current).
Press P7 to select the desired trigger

mode:
L17 ON selects 2 times trigger function.
When trigger is pressed, welding starts.
When trigger is released, welding stops.
L18 ON selects 4 times trigger function.
When trigger is pressed, welding starts.
When trigger is released, welding contin-

ues.
When trigger is pressed and released a

second time, welding stops.

L19 ON selects 3 levels trigger function.
When trigger is pressed, welding starts

with level 1 parameters.
When trigger is released, welding contin-

ues with main parameters.
When trigger is pressed a second time,

welding continues at level 2 parameters.
When trigger is released the second time,

welding stops.

.

L19 trigger mode is useful for thin ma-
terials and for a crater fill sequence.

L20 ON means weld output power is pres-

ent at weld connectors. This LED must be

on for the STICK process to enable weld-

ing. LED will turn on when weld output pow-

er is present at weld connectors for MIG

and TIG processes.

L17

L18

L19

L20

P7

Advertising