6 - 10 Symbol MiniScan MSXX04 Series Integration Guide

Symbol MS2204VHD 2D Decode Zone

Figure 6-6

Symbol MS2204VHD 2D Slab/Raster Decode Distances

In.

cm

0

10 mil, 35% MRD

Depth of Field

5.75

Note: Typical performance at 68˚F (20˚C) on high quality symbols
in normal room light. Y-module dimension = 3X.
Vcc = 5V

1

2

5

6

0

5.1

5.1

25.4

15.2

4.0 mil

1.90

3.00

3

15.2

4

10.1

3.00

0

In. cm

W

i

d

t

h

o

f

F

i

e

l

d

0

1.25

2.5

1.25

2.5

3.18

6.35

3.18

6.35

6.6 mil

4.75

1.50

MS-2204VHD

NOTE

Not optimized for omnidirectional mode.