Warning – Middleby Marshall PS500 User Manual

Page 5

Advertising
background image

5

ENGLISH

SECTION 2 - INSTALLATION

WARNING

Keep the appliance area free and clear of combustibles.

WARNING

Do not obstruct the flow of combustion and ventilation air to and from your oven. There must be no

obstructions around or underneath the oven. Constructional changes to the area where the oven is

installed shall not affect the air supply to the oven.

NOTE

There must be adequate clearance between the oven and combustible construction. Clearance

must also be provided for servicing and for proper operation.

NOTE

An electrical wiring diagram for the oven is located inside the machinery compartment.

NOTE

All aspects of the oven installation, including placement, utility connections, and ventilation requirements,

must conform with any applicable local, national, or international codes. These codes supercede the require-

ments and guidelines provided in this manual.

Table 1-5: Gas orifice and pressure specifications (per oven cavity)

Supply (inlet) Pressure (mbar)

Main

Pilot

IE,IT,PT,

AT,CH,DK,

Orifice

Rated

Orifice

Orifice

ES,GB

D E

N L

BE,FR

FI,SE

(manifold)

Heat

Gas Type

dia.

dia.

II

2H3+

II

2ELL3B/P

II

2L3B/P

II

2E+3+

II

2H3B/P

pressure

Input

PS555G Natural, G20

5.79mm

0.635mm

20

20

--

20-25

20

9.0 mbar

44kw

Natural, G25

5.79mm

0.635mm

--

20

25

--

--

12.0 mbar

44kw

Natural, G20, G25

5.79mm

0.635mm

20

20

25

20-25

20

9.0 mbar

44kw

Liquid, G30

3.33mm

0.381mm

29-37

--

28-30

29-37

50

23.9 mbar

44kw

Liquid, G30, G31

3.33mm

0.381mm

--

50

30

--

50

23.9 mbar

44kw

PS570G Natural, G20

6.35mm

0.635mm

20

20

--

20-25

20

9.0 mbar

50kw

Natural, G25

6.35mm

0.635mm

--

20

25

--

--

12.0 mbar

50kw

Natural, G20, G25

6.35mm

0.635mm

20

20

25

20-25

20

9.0 mbar

50kw

Liquid, G30

3.53mm

0.381mm

29-37

--

28-30

29-37

50

23.9 mbar

50kw

Liquid, G30, G31

3.53mm

0.381mm

--

50

30

--

50

23.9 mbar

50kw

Table 1-4: Electrical specifications for PS555G and PS570G gas ovens (per oven cavity)

Main Blower

Control Circuit

Phase

Freq

Electrical system

Current draw (avg.) *

Poles

Wires

Voltage

Voltage

kW rating

230V

120V conveyor speed controller

1 Ph

50Hz

2.3kW

10A *

2 Pole

3 Wire

(w/transformer);

(2 hot, 1 gnd)

all other control circuits 230V

* CAUTION: The current draw shown in the chart above is an average value for normal operation. The initial amperage draw

on oven startup may exceed the listed value.

WARNING

The oven must be installed on an even (level) non-flammable flooring and any adjacent walls must be non-

flammable. Recommended minimum clearances are specified in the Description section of this Manual.

WARNING -

After any conversions, readjustments, or service work on the oven:

•

Perform a gas leak test.

•

Test for correct air supply, particularly to the burner blower.

•

Test for proper combustion and gas supply.

•

Check that the ventilation system is in operation.

Advertising