SECTION 2 - INSTALLATION

458mm minimum

(Typical - both

ends of oven)

76mm

minimum

203mm

minimum

51mm

minimum

Fig. 2-3 - Ventilation System

4

3

2

1

5

CODES SUPERSEDE THE RECOMMENDATIONS SHOWN IN

THIS MANUAL.

The rate of air flow exhausted through the ventilation system

may vary depending on the oven configuration and hood design.

Consult the hood manufacturer or ventilation engineer for these

specifications.

To avoid a negative pressure condition in the kitchen area,

return air must be brought back to replenish the air that was

exhausted. A negative pressure in the kitchen can cause heat-

related problems to the oven components as if there were no

ventilation at all. The best method of supplying return air is

through the heating, ventilation and air conditioning (HVAC)

system. Through the HVAC system, the air can be temperature-

controlled for summer and winter. Return air can also be

brought in directly from outside the building, but detrimental

effects can result from extreme seasonal hot and cold

temperatures from the outdoors.

NOTE: Return air from the mechanically driven system must not

blow at the opening of the baking chamber. Poor oven baking

performance will result.

C. Other ventilation concerns
•

Special locations, conditions, or problems may require the

services of a ventilation engineer or specialist.

•

Inadequate ventilation can inhibit oven performance.

•

It is recommended that the ventilation system and duct

work be checked at prevailing intervals as specified by the

hood manufacturer and/or HVAC engineer or specialist.

A. Requirements
CAUTION

Gas oven installations REQUIRE a mechanically driven

ventilation system with electrical exhaust air sensing control.
A mechanically driven ventilation system is STRONGLY

RECOMMENDED for electric oven installations.
PROPER VENTILATION OF THE OVEN IS THE

RESPONSIBILITY OF THE OWNER.

B. Recommendations
NOTE THAT THE HOOD DIMENSIONS SHOWN IN FIGURE 2-

3 ARE RECOMMENDATIONS ONLY. LOCAL, NATIONAL, AND

INTERNATIONAL CODES MUST BE FOLLOWED WHEN

INSTALLING THE VENTILATION SYSTEM. ANY APPLICABLE

III. VENTILATION SYSTEM

IMPORTANT

Where national or local codes require the

installation of fire suppression equipment or

other supplementary equipment, DO NOT mount

the equipment directly to the oven.

MOUNTING SUCH EQUIPMENT ON THE OVEN MAY:

•

VOID AGENCY CERTIFICATIONS

•

RESTRICT SERVICE ACCESS

•

LEAD TO INCREASED SERVICE EXPENSES

FOR THE OWNER

Fig. 2-2 - Installation Kit

II. INSTALLATION KIT - see Figure 2-2

NOTE: One Installation Kit is required for each oven cavity.

Item Qty.

Part No.

Description

1

1

35900-0148

Conveyor Rear Stop

2

1

35000-1103

Conveyor End Stop

3

1

47008

Owner's Operating & Installation Manual

4

1

1002040

Authorized Service Agency Listing

ADDITIONAL COMPONENTS FOR PS555G AND PS570G GAS OVENS:

5

1

33120-0053

Gas Pipe Nipple

Advertising