Cooling and Fan Installation

The HM-1S depends on natural convection to cool the

heatsinks that absorb heat from the amplifiers and radiate

the heat into the surrounding air space. Natural convection

requires free air in back of, and underneath the HM-1S to

allow air to flow up over the heatsinks. The HM-1S reaches

an equilibrium temperature in approximately 15 minutes

at a steady operating level.
In free air, at a typical room temperature of 25°C, the HM-

1S reaches an equilibrium temperature of

• 40°C in a quiescent state (no audio signal);
• 60°C at a moderate operating level (occasional

limiting);

• 75°C at the maximum operating level (continuous

limiting), or at a moderate level with a subwoofer.

If the temperature reaches 85°C, the thermal limiters

activate (see Protection and Limiting) to prevent high

source levels from further increasing the temperature

and damaging the drivers and electronics. The thermal

limiters provide 30 dB of muting until the temperature

decreases to 75°C.
The HM-1S can be cooled by two fans, available as an

accessory kit. The fans should be used if:

• the HM-1S is enclosed in a soffit or ceiling mount

without adequate space for natural convection;

• the HM-1S is used in hot ambient temperatures or

direct sunlight;

• the user wishes to avoid accidental contact with the

heatsinks if the rear of the HM-1S is exposed.

Installed fans blow air over the heatsink

The fans attach easily to the two bottom rear corners of

the HM-1S. Use a

5

/

32

” Allen wrench to remove the bottom

screws and install the left and right fans according to the

diagram below. The fans are shipped with a terminal plug

keyed for insertion into the 2-pin fan output connector in

the proper orientation only.
The fan speed is temperature controlled. At a heatsink

temperature of 25°C, the fans turn on at half speed and

increase speed linearly until reaching full speed at

75°C.

Protection and Limiting

The front of the HM-1S has two LEDs that indicate power and

limiter activity. The right LED is green when power is ap-

plied. This LED turns red if thermal limiting occurs (de-

scribed in the section Cooling and Fan Installation) until the

temperature decreases to 75°C.
The left LED indicates driver limiter activity with a vari-

able intensity red color; full illumination occurs at thermal

limiting.

Rigging

!

Do not drill into the HM-1S Cabinet.

The HM-1S is not designed for use with rigging systems.

For rigging needs, Use the Standard Contractors version

HM-1 cabinets which can be easily fitted for omni- mounts,

and other rigging options.