G. TEST MODE

This function is intended to simplify the gas valve adjustment if needed. Listed below are the
recommended limits on each Munchkin Heater and the Combustion Settings. Automatic modulation
does not take place when the controller is in Test mode, only temperature limitation based on the
Munchkin Central Heating set point. The user will be allowed to increase or decrease the fan speed
by pressing in either the

S1/-

or

S2/+

keys.

To activate the Test mode simply press the

S2/+

and

S3/Program

key together for 1 second. Once

activated, you will see in the display

Ser

and the actual fan speed. The measurement of the

combustion levels should always be taken at the highest and lowest fan speed. After 10 minutes, the
Test mode stops automatically. To exit Test Mode press

S1/-

and

S2/+

key together for 1 second.

H. TO TURN OFF GAS TO APPLIANCE

1. Set the thermostat to lowest setting.
2. Turn off all electric power to the appliance if service is to be performed.
3. Remove the front cover.
4. Turn gas shutoff valve to "off".
5. Install front cover.

START-UP PROCEDURES / SERVICING

Fig. 6-2

DANGER

Water temperature over 125 degrees F. can cause severe burns
instantly, or death from scalds. Children, disabled, and elderly
are at highest risk of being scalded. See instruction manual
before setting temperature at water heater. Feel water before
bathing or showering! Temperature limiting valves are available.

Fig. 6-1

COMBUSTION SETTINGS

HIGH FIRING RATES and LOW FIRING RATES ON ALL MODELS

Natural Gas

Propane LP

Carbon CO ppm Monoxide

Carbon CO

2

% Monoxide

low

high

low

high

0–20 ppm

70 ppm–135 ppm

0–20 ppm

80–150 ppm

8-1/2% – 9-1/2%

8-1/2% – 9-1/2%

9-1/2% – 10-1/2%

9-1/2% – 10-1/2%