9. Fit tubing provided into the proper place, as shown.

Cut ice machine suction line to fit new tubing.
Deburr suction line before fitting new tubing in.


NOTE: IF REPLACING COMPRESSOR INTO A

REMOTE ICE MACHINE, MAKE SURE TO
FIRST FOLLOW INSTRUCTIONS A, B, AND C
BELOW, BEFORE PROCEEDING TO
INSTRUCTION #10.

A. Replace elbow with “T” fitting.

B. Replace HPR valve and L-shaped tube that was

removed earlier. Adjust to fit without rubbing
against any other parts of the machine.


C. Return to instruction #10.

10. Place armaflex insulation provided in kit on suction

line, as shown in picture below. Slide insulation up
tubing and secure while brazing.

11. Braze all tubing into place. Purge system with

nitrogen during all brazing operations on the ice
machine.


12. Use electrical tape to seal suction line insulation.

13. Reattach the wiring harness to the compressor.

14. Replace the filter/dryer before evacuating the

machine. Make sure that the filter/dryer tubing is
not rubbing against the compressor.

15. Evacuate machine to 500 microns.




8006183

Sheet 2 of 3

06/25/01

16. Charge the machine with the nameplate charge.