Volt-ampere curves, Connecting to weld output terminals, 3. volt-ampere curves – Miller Electric DVI-2 R User Manual

Page 17: 4. connecting to weld output terminals

Advertising
background image

.

A complete Parts List is available at www.MillerWelds.com

OM-232 386 Page 13

4-3.

Volt-Ampere Curves

The volt-ampere curves show the
minimum and maximum voltage
and amperage output capabilities of
the welding power source. Curves
of other settings fall between the
curves shown.

.

Ranges 4, 5, and 6 apply to 230
VAC only.

ssb1.1 10/91 − 199 212

0

5

10

15

20

25

30

35

0

50

100

150

200

250

DC AMPERES

DC VOL

TS

Range 1

Range 2

Range 3

Range 4

Range 5

Range 6

4-4.

Connecting To Weld Output Terminals

803 778-A

!

Turn off power before connecting to
weld output terminals.

!

Failure to properly connect weld
cables may cause excessive heat
and start a fire, or damage your ma-
chine.

1

Weld Output Terminal

2

Supplied Weld Output Terminal Nut

3

Weld Cable Terminal

4

Copper Bar

Remove supplied nut from weld output ter-
minal. Slide weld cable terminal onto weld

output terminal and secure with nut so that
weld cable terminal is tight against copper
bar. Do not place anything between weld
cable terminal and copper bar. Make
sure that the surfaces of the weld cable
terminal and copper bar are clean.

Tools Needed:

3/4 in (19 mm)

4

2

3

Do not place

anything between

Correct Installation

Incorrect Installation

1

weld cable terminal

and copper bar.