VOLTAGE CHARTS

z

NOTE: Q402 and Q409 are not fitted on this model series.

z

NOTE: Q9, 10, 15, 19, 20, 23 and 28 - 32 are not fitted on this model series.

z

NOTE: ~ indicates approximate voltage. Actual voltage may vary.

CONTROL CIRCUIT

RX

TX

REF #

B

C

E

B

C

E

Q401

4.4

0.0

5.0

0.3

5.0

5.0

Q403

0.0

4.6

GND

0.0

4.6

GND

Q404

5.0

2.2

2.0

0.0

7.0

0.0

Q405

5.0

1.8

1.7

5.0

1.8

1.7

Q406

4.0

0.0

5.0

2.0

5.0

5.0

Q407

0.0

4.5

GND

5.0

0.0

GND

Q408

0.0

5.0

GND

2.0

0.0

GND

Q410

4.3

0.0

5.0

4.3

0.0

5.0

Q411

0.0

-

GND

0.0

0.0

GND

Q412

0.0

7.5

7.5

0.0

7.5

7.5

Q413

7.5

0.0

GND

7.5

0.0

GND

MAIN CIRCUIT

RX

TX

REF #

B

C

E

B

C

E

Q1

0.6

5.0

5.0

0.6

5.0

5.0

Q2

5.0

0.0

5.0

0.3

4.7

5.0

Q3

0.0

4.7

5.0

5.0

0.0

5.0

Q4

0.0

5.0

5.0

0.0

5.0

5.0

Q5

4.7

0.0

5.0

4.7

0.0

5.0

Q6

4.0

18.0

5.0

4.0

18.0

5.0

Q7

18.0

~3.0

18.0

18.0

~4.0

18.0

Q8

5.0

0.0

5.0

5.0

0.0

5.0

Q11

0.0

3.0

0.0

0.0

4.0

0.0

Q12

1.6

4.5

1.0

0.0

0.0

0.0

Q13

4.6

4.6

4.0

0.0

0.0

0.0

Q14

0.0

0.0

0.0

4.6

4.6

4.0

Q16

0.0

0.0

0.0

1.4

4.8

0.8

Q17

0.0

0.0

0.0

0.6

3.0

GND

Q18

0.0

0.0

0.0

5.0

0.2

GND

Q21

0.0

0.0

0.0

~3.0

~5.6

~2.4

Q22

7.5

0.0

7.5

6.9

~7.0

7.5

Q24

0.0

4.5

GND

0.0

0.0

GND

Q25

0.7

4.0

GND

0.0

0.0

GND

Q26

-

-

-

0.0

0.0

0.0

Q27

0.7

NOISE

GND

0.0

0.0

GND

Q33

7.2

4.0

7.5

6.9

7.5

7.5

Q34

0.0

6.6

GND

2.0

0.0

GND

Advertising