Microsoft STOREXPRESS DSE4XM1 User Manual

Page 45

Advertising
background image

March 10, 2009

Dolphin Interconnect Solutions

45

www.dolphinics.com

Sample Output

The fio-status command alone displays abbreviated information on all installed
ioDrives:

fio-status

Found 2 ioDrives in this system.

Fusion-io driver version: 1.2.4.3

fct0 Attached

ioDimm3 SN:0719 Firmware v11791

92 GBytes unformatted capacity.

fct1 Not attached

ioDimm3 SN:0299 Firmware v11791

154 GBytes unformatted capacity.

The fio-status command with the –a parameter and no device name displays all the
information available on every installed ioDrive.

fio-status -a

Found 2 ioDrives in this system.

Fusion-io driver version: 1.2.4.3

fct0 Attached

-c

Count: Report only the number of ioDrives installed.

-a

All: Print all available information for each device. The fio-status
command displays the following information:

Serial number

Part number

Manufacturer's name

Manufacturing date

Firmware version at manufacturing time

Size of the device, out of total capacity

NAND manufacturer

NAND cell type (SLC, MLC, or
unknown)

Size of the device in blocks

Size of a block in pages

Size of a page in bytes (including ECC
overhead)

Number of pads, planes and banks

Size of an ECC-protected unit (includ-
ing check-bit overhead)

FPGA ID

Hardware UID

Bus ID

Vendor ID

Subsystem vendor and device IDs

Device ID

PCI slot number

Internal temperature (avg. and max.,
since driver load) in degrees Centigrade

Ambient temperature, in degrees Centi-
grade

Internal voltage: avg. and max.

Auxiliary voltage: avg. and max.

Health status: Healthy, Marginal, or
Degraded, based on the percentage of
good erase blocks on the device

Percentage of good data

Percentage of good blocks

Percentage of good metadata

Advertising
This manual is related to the following products: