E-fx-hb-xx00 in the network, Technical specifications – Milan Technology E-FX-HB-1600 User Manual

Page 2

Advertising
background image

E-FX-HB-xx00 IN THE NETWORK

Install one E-FX-HB-xx00
hub and use fiber cable
to set up a workgroup by
connecting the hub to
terminal devices.

Install an optional
backbone uplink adaptor at
the back of the hub and use
copper or fiber cable to
connect the workgroup to a
network backbone.

Install an optional expansion
adaptor at the back of up to
five (5) hubs and then use
expansion adaptor cables to
connect the hubs into a
stack that functions as one
Class A repeater.

TECHNICAL SPECIFICATIONS

Standards

IEEE 802.3

Dimensions

17.25" x 8.5" x 1.7"

(437 mm x 216 mm x 43 mm)

Power

Input Range:

100 to 240 VAC at 50 or 60 Hz, 3.0 A maximum.
Rated at 40 watts maximum.

Environment

Operating Temperature:

0° to 50°C (32° to 122° F )

Storage Temperature:

-15° to 65°C (5° to 149° F )

Humidity

5% to 95%, non condensing

Altitude

0 to 10,000 feet

Warranty

Lifetime

DECLARATION OF CONFORMITY

Name of Mfg:

Transition Networks
6475 City West Parkway, Minneapolis MN 55344 USA

Model:

E-FX-HB-xx00 Series Unmanaged Fiber Hub

Part Number:

E-FX-HB-1600, E-FX-HB-1600(SC), E-FX-HB-0800,
E-FX-HB-0800(SC)

Regulation:

EMC Directive 89/336/EEC

Purpose: To declare that the E-FX-HB-1600 or E-FX-HB-0800 to which this

declaration refers is in conformity with the following standards.

EMC-CISPR 22: 1985 Class A; EN 55022: 1988 Class A; EN 50082-1:1992;
EN 60950 A4:1997; IEC 801.2, IEC 801.3, and IEC 801.4; IEC 950

I, the undersigned, hereby declare that the equipment specified above conforms to the

above Directive(s) and Standard(s).

_November 10, 1999_____

Stephen Anderson, Vice-President of Engineering

Date

1

3

2

STAT

PWR

4

5

7

6

8

9

11

10

12

13

15

14

16

COL

ACT

100BASE-FX

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

ACT

STAT

GFT

BB

1

3

2

STAT

PWR

4

5

7

6

8

9

11

10

12

13

15

14

16

COL

ACT

100BASE-FX

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

ACT

STAT

GFT

BB

to hub, switch, or router

to hub, switch, or router

1

3

2

STAT

PWR

4

5

7

6

8

9

11

10

12

13

15

14

16

COL

ACT

100BASE-FX

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

ACT

STAT

GFT

BB

1

3

2

STAT

PWR

4

5

7

6

8

9

11

10

12

13

15

14

16

COL

ACT

100BASE-FX

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

ACT

STAT

GFT

BB

1

3

2

STAT

PWR

4

5

7

6

8

9

11

10

12

13

15

14

16

COL

ACT

100BASE-FX

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

ACT

STAT

GFT

BB

1

3

2

STAT

PWR

4

5

7

6

8

9

11

10

12

13

15

14

16

COL

ACT

100BASE-FX

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

ACT

STAT

GFT

BB

1

3

2

STAT

PWR

4

5

7

6

8

9

11

10

12

13

15

14

16

COL

ACT

100BASE-FX

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

ACT

STAT

GFT

BB

Advertising
This manual is related to the following products: