INSTALLATION

Optionally Install Expansion Adapter

WARNING: Remove AC line cord from power source before installing
expansion adaptor in E-FX-HB-xx00. Failure to observe this warning could
result in personal injury or death.

CAUTION: Wear a grounding device and observe electrostatic discharge
precautions when installing Expansion Adapter in the E-FX-HB-xx00. Failure
to observe this caution could result in damage to, and subsequent failure of,
Expansion Adapter.

To install the expansion adapter in the E-FX-HB-xx00:

1.

Locate expansion adapter plate at back of E-FX-HB-xx00.

2.

Remove expansion adapter plate by using flatblade screwdriver to
remove two (2) screws that secure expansion adapter plate to back
of E-FX-HB-xx00.

NOTE: Retain screws for step 5. (Optionally discard expansion
adapter plate.)

3.

Carefully slide expansion adapter, component side up, into
installation space revealed by removal of expansion adapter plate.

CAUTION: Do NOT force the connection. Failure to observe this

caution could result in equipment damage and subsequent failure.

4.

Press component on expansion adapter securely against internal
mating E-FX-HB-xx00 component until expansion adapter faceplate
is flat against E-FX-HB-xx00 chassis.

5.

Secure expansion adapter by installing retained screws through
expansion adapter into E-FX-HB-xx00 chassis.

YES

Continue at step 7.

7.

Is one (or more) of the 100BASE-FX STAT(us) LEDs illuminated
continuously?
YES

Continue at step 10

NO

Continue at step 8.

8.

Does one (or more) of the 100BASE-FX STAT(us) LEDs blink on
and off?
YES

Check fiber cables for proper connection.

Verify that TX and RX cables on E-FX-HB-xx00 are connected to RX
and TX ports, respectively, on terminal device. (See page 9.)

Ensure that terminal device(s) is/are powered.

Contact Technical Support: (800) 260-1312.

NO

Continue at step 9.

9.

Is one (or more) of the 100BASE-FX STAT(us) LEDs dark?
YES

The port is (or ports are) partitioned; investigate the attached
terminal device(s).

Contact Technical Support: (800) 260-1312.

NO

Continue at step 10.

10.

Is one (or more) of the 100BASE-FX ACT(ivity) LEDs
illuminated?
YES

The port is (or ports are) operational and receiving data.

NO

Disconnect and reconnect the 100BASE-FX cable to restart the
initialization process.

Restart the terminal device(s) to restart the initialization process.

Contact Technical Support: (800) 260-1312.