CABLE SPECIFICATIONS

Twisted Pair Cable and Connector Specifications

MA-TX

Category 5 twisted-pair copper

Either shielded twisted-pair (STP) or unshielded twisted-pair (UTP) can be used. .

CATEGORY 5:

Gauge

24 to 22 AWG

Attenuation

22.0 dB /100m @ 100 MHz

Maximum Cable Distance*:

100 meters

Twisted pair connection requires two active pairs configured as straight-through
OR as crossover. The two active pairs in an Ethernet™ network are pins 1 & 2
and pins 3 & 6. Use only dedicated wire pairs (such as blue/white & white/blue,
orange/white & white/orange) for the active pins.

Fiber Cable

MULTIMODE

Fiber Optic Cable Recommended:

62.5 / 125 µm multimode fiber

Optional:

100 / 140 µm multimode fiber
85 / 125 µm multimode fiber
50 / 125 µm multimode fiber

Bit error rate:

10

-11

E-FX-HB-xx00, MA-FST

1300 nM

Fiber-optic Transmitter Power:

min: -16.0 dBm

max: -9.0 dBm

Fiber-optic Receiver Sensitivity:

min: -35.0 dBm

max: -14.0 dBm

Link Budget

19 dB

Typical Maximum Cable Distance:*

2 kilometers

E-FX-HB-xx00(SC), MA-FSC

1300 nM

Fiber-optic Transmitter Power:

min: -16.0 dBm

max: -9.0 dBm

Fiber-optic Receiver Sensitivity:

min: -35.0 dBm

max: -14.0 dBm

Link Budget

19 dB

Typical Maximum Cable Distance:*

2 kilometers

SINGLEMODE

Fiber Optic Cable Recommended:

9 µm singlemode fiber

Bit error rate:

10

-11

MA-FSM

1300 nM

Fiber-optic Transmitter Power:

min: -16.0 dBm

max: -9.0 dBm

Fiber-optic Receiver Sensitivity:

min: -35.0 dBm

max: -14.0 dBm

Link Budget

19 dB

Typical Maximum Cable Distance:*

20 kilometers

*Actual distance dependent upon physical characteristics of network installation.

Using the 512-Bit Rule

When configuring Fast Ethernet™ networks, use the 512-bit rule to determine
masimum cable lengths for each half-duplex collision domair.

In a half-duplex network, maximum
cable lengths are determined by the
round trip delay limitations of each Fast
Ethernet

collision domain. (Switches

and routers divide the network into
separate Ethernet™ collision domains.)
The 512-Bit Rule determines maximum
distances by calculating the collision
domain round-trip delay in bit-times.

To calculate a collision domain
round-trip delay in bit-times, find
the longest path between any two
terminal devices in the collision
domain. Calculate the round trip
delay by multiplying the length of
the cable (in meters) by the delay
per meter (in bit-times (BT)), then
take the sum of all cable delays
plus station (DTE), repeater, and
multi-port media converter port
delays. If the result is less than or
equal to 512 bit-times, the path is
good.

to hub, switch or router

1

3

2

STAT

PWR

4

5

7

6

8

9

11

10

12

13

15

14

16

COL

ACT

100BASE-FX

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

ACT

STAT

GFT

BB

1

3

2

STAT

PWR

4

5

7

6

8

9

11

10

12

13

15

14

16

COL

ACT

100BASE-FX

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

ACT

STAT

GFT

BB

1

3

2

STAT

PWR

4

5

7

6

8

9

11

10

12

13

15

14

16

COL

ACT

100BASE-FX

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

ACT

STAT

GFT

BB

1

3

2

STAT

PWR

4

5

7

6

8

9

11

10

12

13

15

14

16

COL

ACT

100BASE-FX

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

ACT

STAT

GFT

BB

1

3

2

STAT

PWR

4

5

7

6

8

9

11

10

12

13

15

14

16

COL

ACT

100BASE-FX

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

ACT

STAT

GFT

BB

1

3

2

STAT

PWR

4

5

7

6

8

9

11

10

12

13

15

14

16

COL

ACT

100BASE-FX

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

ACT

STAT

GFT

BB

1

3

2

STAT

PWR

4

5

7

6

8

9

11

10

12

13

15

14

16

COL

ACT

100BASE-FX

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

ACT

STAT

GFT

BB

1

3

2

STAT

PWR

4

5

7

6

8

9

11

10

12

13

15

14

16

COL

ACT

100BASE-FX

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

ACT

STAT

GFT

BB

Collision Domain

Class II

Hub

30 meters TP

@ 1.11BT/meter

= 33.3BT

5 meters TP

@ 1.11BT/meter

= 5.55BT

= 140BT

Class I

Hub

= 140BT

20 meters TP

@ 1.11BT/meter

= 22.2BT

DTE=50BT

50.00BT

+22.20BT

+140.00BT

+5.55BT

+140.00BT

+33.30BT

+50.00BT

___________

= 441.05BT

Switch

= 50BT

Class I repeater

140 BT

Class II repeater

92 BT

Class I TX/FX media converter

130 BT

Class II TX/FX media converter

92 BT

DTE (PC, switch, router)

50 BT

1 meter CAT.5 TP cable

1.11 BT

1 meter fiber cable

1 BT

Fast Ethernet switch

50 BT

Cascade two repeater stacks by
connecting fiber cable from a
connector at the front of the
first hub to a connector at the
front of the second hub.

Crossover

1
2

3
6

Straight Through

Twisted Pair #1

Twisted Pair #1

Twisted Pair #2

Twisted Pair #2

1
2

3
6

1
2

3
6

1
2

3
6

Advertising
This manual is related to the following products: