4.2 Replacement of the battery module

4. Maintenance

Removal of the battery module

This operation may be carried out with the UPS supplying power to the load.

Safety rules

Batteries constitute a danger (electrical shock, burns). The short-circuit current may be very high. Precautions
must be taken for all handling:

remove all watches, rings, bracelets and any other metal objects;

use tools with insulated handles.

A - Use a finger to unclip the small plate
with the MGE logo on the front panel of the
UPS.
B - Remove the two screws.

C - Pull away the left-hand side of the front
panel.
D - Remove the screw securing the safety
connector.

E - Remove the safety connector.