SECTION 9 − HIGH FREQUENCY

9-1. Welding Processes Requiring High Frequency

high_freq1 11/96 − S-0693

1

High-Frequency Voltage

Helps arc jump air gap between

torch and workpiece and/or

stabilize the arc.

1

TIG

Work

9-2. Incorrect Installation

50 ft

(15 m)

S-0694

Sources of Direct High-Frequency

Radiation
1

High-Frequency Source (welding power

source with built-in HF or separate HF

unit)

2

Weld Cables

3

Torch

4

Work Clamp

5

Workpiece

6

Work Table

Sources of Conduction of High

Frequency
7

Input Power Cable

8

Line Disconnect Device

9

Input Supply Wiring

Sources of Reradiation of High

Frequency
10 Ungrounded Metal Objects
11 Lighting
12 Wiring
13 Water Pipes and Fixtures
14 External Phone and Power Lines

Weld Zone

13

9

8

7

1

2

4

5

6

3

10

11, 12