Warning, Caution – Milwaukee MK-Manta I User Manual

Page 7

Advertising
background image

6

MANTA I

Revision 03/05, Effective Date March 2, 2005

7

MANTA I

Revision 03/05, Effective Date March 2, 2005

Vacuum Base Gasket

Final Assembly

Assembly

Main Assembly

Feed Handle and
Meter Box

For your own safety and protection, do not attempt to operate this drill until it is

completely assembled and installed according to these instructions, and until

you understand the machines capabilities and the potential hazards associated

with it.

Step 1 The Manta I is shipped with the main part of the Manta mounted

backwards on the Vacuum base. Remove the nut and bolt that hold the main

assembly to the Vacuum base observing the following precaution. Turn the

Vacuum base around to the correct orientation, slide the small base all the way

back on the vacuum base, and reinstall the nut and bolt.

When removing the nut and bolt that holds the main assembly to the vacuum

base, the Manta will tip forward. Be sure to hold the Manta when removing the

vacuum base.

To set the Manta so that it will stand up, loosen the carraige lock knob (be sure

to hold the carraige) and move the carraige down to a position where the end of

the motor spindle just touches the ground.

Step 2 Install the leveling screws (8), screwing four (4) into each base.

Step 3 Install the feed handles (1) and knobs (2) by screwing one knob onto

the end of the handle, then slip thru hub and attach other knob.

Step 4 Remove the Manta from the vacuum base by removing the nut and

bolt that holds the main assembly to the vacuum base. Set the Manta aside,

observing the following precaution.

Turn the vacuum base over. Press the gasket into the groove in the underside of

the base. The gasket is cut, at the factory, to the correct length, so that the two

ends will butt together once the gasket is installed.

Step 5 Assemble the two pieces of the water valve, and install the valve, into

the water swivel, on the motor, just above the spindle (see motor literature).

Plug the cord from the motor into the upper outlet on the meter box (the one

opposite the motor on-off switch. The other outlet on the meter box is for the

vacuum pump.

WARNING

!

CAUTION

!

Advertising