Fig. 25 Combustible side wall protection and hearth extension dimensions.

Minimum Wall Clearances

WITH
Noncombustible
Surround Facing

WITHOUT
Noncombustible
Surround Facing

Minimum Hearth Extension Dimensions

(for On-Site Construction)

G

H

G

J

Seal cracks
between the
fireplace
and hearth
extension with
noncombustible
material

"Z" Safety strips
must overlap

¹⁄₂

" minimum

May install
noncombustible
decorative
covering
OR .018" min.
sheet metal

Fireplace
Opening

Combustible
Floor

9

¹⁄₂

" Required

Firebox

Opening

A - Min. clearance
to combustible
perpendicular wall

B - Min. clearance
to combustible
perpendicular wall when
using noncombustible wall shield*

Side
Wall

Side
Wall

F**

C**

E

E

D

4" Brick
(Example material)

Combustible material permitted within shaded area.

* Noncombustible wall shield requires 1" EH2416

insulation (minimum R Value = 1.85) between decorative
noncombustible rigid covering and combustible wall.
Minimum height and width is 40" x 40".

** Dimension/degree of angle will vary depending on thickness

of noncombustible surround facing.

4"

NOTE: No material may
cover black cast face.
Hearth extension must be
flush with bottom of fireplace.

1" Min.

1" Min.
EH2416 or
Equal "R" Value

Shaded area starts
1/2" away from
edge of unit

A

B

C

D

E

F

G

H

J

EWF36A

24”

12”

17

°

25

°

12”

8”

8”

18”

57”

610mm 305mm

305mm

203mm 203mm

457mm 1448mm