The chimney system – Majestic Appliances EWF36A User Manual

Page 24

Advertising
background image

24

Vermont Castings EWF36A

20005167

Replaceable Fiberglass Gaskets

Gasket Size...

...And The Parts It Seals

1/2"

The door to the front

5/8”

Door to the hearth brick support

3/16"

The glass seal tothe door

1/2”

Cat holder to top plate

1/2” Braided

Damper to top plate

Should you need to change a replaceable gasket, wait
until the fire is out and the stove has cooled. Be sure to
follow the standard safety procedure for working with
dusty materials: Wear safety goggles and a dust mask.
The procedure for replacing gaskets is the same,
regardless of the gasket location. Four easily-accom-
plished steps are involved:

1. Remove the existing fiberglass gasket by grasping

an end and pulling firmly.

2. Use a wire brush or the tip of a screwdriver to clean

the channel of any remaining cement or bits of
gasket.

3. Apply a thin bead of stove cement to the newly-

cleaned groove.

4. Pack a new gasket into the groove. Wait until you

have placed all but a couple inches from the end
before you trim the end to an exact fit.

5. Place door back on fireplace, latch door and keep

closed for 1/2 hour to insure cement has set.

Replacing the Door Gaskets

Remove the door by lifting it straight up off its hinge
pins. Lay it face down on a padded surface.

Follow steps 1-4 as described above.

Replace Damaged Door Glass Immediately

Do not operate the fireplace with damaged glass door.
Use the following procedure for glass replacement.

NOTE: Replace glass only with the replacement glass
made for this unit, available from your authorized
dealer.

Remove the door and loosen the retaining clips which

hold the glass to the door frame. Remove clips. Use
caution when handling broken glass.

Examine the gasket that seals the glass to the door

frame. Replace if necessary with gasket obtained from
your local Vermont Castings’ Authorized Dealer. See
the directions for gasket replacement on Page 23.

Check the flat surface of the door frame, and clear

away debris if necessary.

Install the new glass.

Secure the clips, being careful not to overtighten. Be

sure the glass is firmly seated against the gasket.

Replace door.

The Chimney System

A Clean Chimney System is

Safer and Works Better

Although the combustion system in the EWF36A can
reduce creosote formation dramatically, it is not a
substitute for regular inspection and cleaning of the
chimney and chimney connector.

Learn to Recognize —

and Avoid — Creosote

The EWF36A has been designed to reduce creosote
build-up significantly. However, regular chimney
inspection and maintenance must still be performed.
For safety, good stove performance, and to protect your
chimney and chimney connector, inspect your chimney
and chimney connector on a regular schedule. Clean
the system if necessary. Failure to keep the chimney
and connector system clean can result in a serious
chimney fire.

When wood is burned slowly, it produces tar, organic
vapors and moisture which combine to form creosote.
The creosote vapors condense in the relatively cool
chimney flue of a slow-burning fire. As a result, creo-
sote residue accumulates on the flue lining. When
ignited, this creosote makes an extremely hot fire within
the flue system that can damage the chimney and
overheat adjacent combustible material. If a significant
layer of creosote has accumulated —1/8" (3mm) or
more — it should be removed to reduce the risk of a
chimney fire.

If you do experience a chimney fire, act promptly to:

Close the primary air control lever and the
damper

Get everyone out of the house.

Call the Fire Department.

You should inspect the system every two weeks during
the heating season as part of a regular maintenance
schedule. To inspect the chimney, let the fireplace cool
completely. Remove the termination top. Then, using a
strong light, sight down into the chimney flue.

Clean the chimney using a specially designed brush the
same size and shape as the flue liner. Flexible fiber-
glass rods are used to run the brush up and down the
liner, causing any deposits to fall to the bottom of the
chimney where they can be removed through the clean-
out door on top of the fireplace.

If you can not do the chimney inspection yourself,
contact your local Vermont Castings' Authorized Dealer,
or engage a professional chimney sweep to perform the
inspection and cleaning of the chimney.