Cleaning the drain pump and non-return valve 55, Cleaning and care, Cleaning the drain pump and non-return valve – Miele PROFESSIONAL PG 8050I User Manual

Page 55

Advertising
background image

Cleaning the drain pump and
non-return valve

If the water has not been drained at the
end of a program the drain pump or the
non-return valve might be blocked.

,

Be careful - glass or bone

splinters could cause injury.

^ Take the triple filter out of the wash

cabinet (see "Cleaning and care" -
Cleaning the filters in the wash
cabinet").

^ Scoop the water out of the cabinet

using a suitable container or utensil.

^ Raise the locking clamp of the

non-return valve.

^ Lift out the non-return valve and rinse

under running water.

^ Remove all foreign objects from the

non-return valve.

The drain pump is located under the
non-return valve (see arrow).

^ Clean any foreign objects from the

drain pump. Turn the drain pump
impeller by hand to check for
objects.

^ Carefully replace the non-return valve

and secure it with the locking clamp.

Cleaning and care