4.0 PLT200 SPECIFICATIONS

Laser Specifications:

Classification: Class 3R (per IEC 60825-1 Ed 1.2 2001-8)

Complies with FDA performance standards for laser products except
for deviations pursuant to Laser Notice No. 50, dated July 26, 2001.

Maximum Laser Output: 3mW
Pulse Duration:

Continuous

Laser Wavelength:

650 nm

Beam Divergence:

< 1.5 mrad

Beam Diameter:

4 x 7 mm typical at 2 meters

Laser Diode Life:

8,000 operating hours MTBF (1 year

warranty)

Non-Contact Specifications:

Ranges:

RPM

5 – 200,000

RPS

0.084 – 3,333.3

RPH

300-999,990

Resolution: Fixed:

1 (10 above 99,999)

Auto-ranging: 0.001 to 1.0 (10 above 99,999)

Accuracy:

±0.01% of reading or resolution limit

Operating Range: up to 25 feet (7.62 m) or up to 70 degrees off

perpendicular to T-5 tape target

Contact Specifications using optional Remote Contact Assembly:

Range:

Contact Tips:

0.5 to 20,000 RPM

10 cm / 12-inch Wheel: 0.5 to 12,000 RPM

Resolution: Fixed:

1 (10 above 99,999)

Auto-ranging:

0.001 to 1.0 (10 above 99,999)

20

8.

Save and
advance

9.

Exit Setup –
Ready to
measure

Measure:

Reset

Lap

Power Off

Unit will remember these settings (including lock on/off) even if turned off
and back on.

DONE, then Units

selected

Manual

Auto

Each press toggles Start and Stop

Start and Stop triggered by
Remote Optical Sensor (ROS)

With Timer stopped -
Resets time to 00:00.0

With Timer running -
Stops at elapsed time to date.
To continue, press again.

OR

9.2 TIMER Operation

Automatic after 90 seconds
if unit not Locked on