Section 2

Installation Instructions

Part Number 14514 2/08

2-7

ADJUSTING DEFROST DURATION

The defrost cycle is terminated by a temperature-
sensing switch located on the suction line, adjacent to
the evaporator coil.

The defrost duration is factory-set. Normally, no
adjustment is required. For a longer defrost time, press
down on the inner dial pointer and rotate the pointer until
the desired time lines up.

TEMPERATURE CONTROLS

The temperature controls are factory-set to maintain an
average temperature of 38

°F in refrigerators, and an

average temperature of 0

°F in freezers.

The temperature variance is 6-8 degrees. A freezer
should run between -2 to -3

°F and +3 to +4°F. A

refrigerator should run between +35 to +36°F and +41 to
+42

°F.

For a different cabinet temperature setting, turn the
temperature control knob or screw, located on the
evaporator coil/blower housing.

Important

The coil defrosts only until the temperature-sensing
switch terminates the cycle, regardless of the
defrost duration that is set.

Important

Setting the temperature control to the coldest setting
may cause the coil and/or air ducts to freeze and ice
up. This will eventually result in a warmer cabinet
temperature.

If ice accumulation occurs and the temperature is
lower than the guidelines, turn the control knob to a
warmer setting.

! Caution

Allow the cabinet to reach proper operating
temperature before filling it with product. Do not
place hot or steaming foods in the cabinet.