Flames from the pilot, front and rear burner should be visually checked as soon as the heater is installed.

In addition, periodically check the flames visually during operation.

CHECKING PILOT FLAME

The pilot flame must always be present when the heater is in operation.

It should just touch the top of the ther-

mocouple tip for natural. See Figure 19 for correct pilot flame.
If the pilot flame does not touch the thermocouple, then the burners cannot function reliably. See Figure 20 for incorrect

shape of pilot flame.
MILLI-VOLT CONTROL

Figure 19 - Correct Appearance of Pilot Flame

Figure 20 - Incorrect Appearance of Pilot Flame

Thermocouple

for Natural

Thermocouple

for LP

Thermocouple

for LP

Thermocouple

for Natural

ROCK WOOL INSTALLATION

Figure 18 - Rock Wool Installation

1. Break rock wool into dime-sized pieces.

2. Place rock evenly across rock wool tray and front burner as shown in

Figure 18.

• Rock wool depth must not be more than 1".
• Do not place rock wool past the bend in rock wool tray.
• Do not place rock wool on rear burner.

FLAME APPEARANCE

Rock Wood

Tray

Rock Wool

Bend in Rock

Wool Tray

Rock wool must be placed
correctly. Placing rock wool
in wrong area will create high
carbon monoxide.

W

ARNING