Troubleshooting w arning, Warning – Martin Fireplaces VFCS20SNV User Manual

Page 24

Advertising
background image

24

58D6003

OBSERVED PROBLEM

When ignitor button is pressed,

there is no spark at ODS/pilot.

Appliance produces unwanted

odors.

Appliance shuts off during use.

Gas odor even when control knob

is in OFF position.

When ignitor button is pressed,

there is spark at ODS pilot, but

no ignition.

POSSIBLE CAUSE

1. Ignitor electrode positioned wrong.

2. Ignitor electrode is broken.

3. Ignitor electrode not connected to ignitor

cable.

4. Ignitor cable pinched or wet. Keep ignitor cable

dry.

5. Broken ignitor cable.

6. Bad piezo ignitor.

7. No battery power (auto spark).

1. Appliance burning vapors from paint, hair

spray, glues, etc.

2. Gas leak.

3. Initial burn off.

1. Not enough fresh air is available for ODS/ pilot

to operate.

2. Low line pressure.

3. ODS/pilot is partially clogged.

4. Defective Thermopile.

5. Restrictions in incoming air flow.

1. Gas leak.

2. Control valve defective.

1. Gas supply turned off or appliance shutoff

valve closed.

2. Air in gas lines when installed.

3. ODS/pilot is clogged.

4. Gas regulator setting is not correct (LPG).

REMEDY

1 Replace ignitor.

2. Replace ignitor.

3. Reconnect ignitor cable.

4. Free ignitor cable if pinched by any

metal or tubing.

5. Replace ignitor cable.

6. Replace piezo ignitor.

7. Replace battery.

1. Ventilate room. Stop using odor causing

products while heater is running.

2. Locate and correct all leaks.

3. Ventilate room and turn unit on high until

odor is gone. Odor should be gone after

2 to 3 hours of continuous use.

1. Open window and/or door for ventila-

tion.

2. Contact local gas company.

3. Clean ODS/pilot.

4. Check pilot flame. Check wire connec-

tions. Check thermopile output — should

be 500 milli-volts across TH/TP and TP

Terminals with ON/OFF switch off.

5. Check for obstructions on bottom of unit.

Check for improper log placement.

1. Locate and correct all leaks.

2. Replace control valve.

1. Turn on gas supply or open manual

shutoff valve.

2. Continue holding down control knob.

Repeat igniting operation until air is

removed.

3. Replace ODS/pilot assembly or get it

serviced.

4. Replace gas regulator at tank.

Note: All troubleshooting items are listed in order of operation.

TROUBLESHOOTING

W

ARNING

Turn appliance OFF and allow to cool
before servicing. Only a qualified
service person should service and
repair the heater.

W

ARNING

Advertising