IMPORTANT SAFETY INFORMATION

Continued from page 3

15. This is an unvented gas-fired heater. It uses air (oxygen)

from the room in which it is installed. Provisions for

adequate combustion and ventilation air must be pro-

vided. See page 8.

16. Keep room area clear and free from combustible materi-

als, gasoline and other flammable vapors and liquids.

17. Unvented gas heaters are a supplemental zone heater.

They are not intended to be a primary heating appli-

ance.

18. Unvented gas heaters emit moisture into the living area.

In most homes of average construction, this does not pose

a problem. In houses of extremely tight construction,

addition mechanical ventilation is recommended.

19. During manufacturing, fabricating and shipping, various

components of this appliance are treated with certain

oils, films or bonding agents. These chemicals are not

harmful but may produce annoying smoke and smells

as they are burned off during the initial operation of the

appliance; possibly causing headaches or eye or lung

irritation. This is a normal and temporary occurrence.

The initial break-in operation should last two to three

hours with the burner at the highest setting. Provide

maximum ventilation by opening windows or doors to

allow odors to dissipate. Any odors remaining after this

initial break-in period will be slight and will disappear

with continued use.

20. Input ratings are shown in BTU per hour and are for

elevations up to 2,000 feet. For elevations above 2,000

feet, input ratings should be reduced 4 percent for each

1,000 feet above sea level. Refer to the National Fuel

Gas Code.

21. The appliance and its appliance main gas valve must be

disconnected from the gas supply piping system during

any pressure testing of that system at test pressures in

excess of 1/2 psig (3.5 kPa).

22. The appliance must be isolated from the gas supply

piping system by closing its equipment shutoff valve

during any pressure testing of the gas supply piping

system at test pressures equal to or less than 1/2 psig

(3.5 kPa).

23. Do not use this room heater if any part has been under

water. Immediately call a qualified service technician

to inspect the room heater and to replace any part of the

control system and any gas control which has been under

water.

24. Never burn solid fuels in an unvented room heater, fire-

place or stove.

25. Do not set kettles or humidifying devices on top of

stove.

26. The stove door/screen must be closed when the appli-

ance is operating. The screen shall have openings for

induction of combustion air.