5. security – Miller Electric DS-64M Swingarc User Manual

Page 29

Advertising
background image

OM-1588 Page 25

8-5. Security

The security feature allows a mini-

mum and maximum range limit to

be defined for Trim, inches per min-

ute (IPM), and ShpArc (see Section

12).
When the security lock is Off, the

full range of values is available for

each parameter.
When the security lock is On, the

range of values available for each

parameter is the defined value plus

or minus the defined range.
For example, if the IPM value is de-

fined as 125, and the range is de-

fined as 50, the actual range of

available IPM is 75 to 175 IPM (125

minus 50, and 125 plus 50).
1

Card Display

2

Moving Line

Moving line is under value that can

be changed. Change program

number to access desired program.
3

Lock On/Off

Toggles security feature On or Off.

Definable values are displayed

when Lock On is selected. Use side

panel controls to change values.
4

Trim And Range Display

5

IPM And Range Display

6

ShpArc And Range Display

Definable Values (Standard

Motor):
Trim: 0−99 Range: 0−99
IPM: 50−780 Range: 0−780
ShpArc : 0−20 Range: 0−20
In the example displays, the

operator could change the value of
Trim to 55 and its Range to

±

10.

Also, the operator could change the

value of IPM to 225 and its Range to

±

100 IPM from programmed

values. If the range settings are left

at 0, the operator cannot change

values from those programmed.

.

The security feature works only when a data card is inserted.

S eq u e n c e
D ua l S c h d
C a r d

> S ec u r i t y

> P r o g

1

L oc k

O f f

1

Press

Mode

Turn

Unit

On

Select

P r o g

1

>L o c k

O f f

2

P r o g

1

>L o c k

O n

T r i m

5 0

R a n g e

0

5 Times

Side Panel

Parameter

Select

Increase/

Decrease

P r o g

1

L o c k

O n

>T r i m

5 0

R a n g e

0

Increase/

Decrease

L o c k

O n

T r i m

5 5

>R a n g e

0

I P M

2 0 0

Increase/

Decrease

Increase/

Decrease

T r i m

5 5

R a n g e

1 0

> I P M

2 0 0

R a n g e

0

T r i m

5 5

R a n g e

1 0

I P M

2 2 5

>R a n g e

0

I P M

2 2 5

R a n g e

1 0

>S h p A r c

0

R a n g e

3

P r o g

1

L o c k

O n

>T r i m

5 5

R a n g e

0

Side Panel

Parameter

Select

Side Panel

Parameter

Select

Side Panel

Parameter

Select

Side Panel

Parameter

Select

Increase/

Decrease

T r i m

5 5

R a n g e

1 0

I P M

2 2 5

>R a n g e

1 0 0

Side Panel

Parameter

Select

L o c k

O n

T r i m

5 5

>R a n g e

1 0

I P M

2 0 0

T r i m

5 5

R a n g e

1 0

> I P M

2 2 5

R a n g e

0

3

4

5

>P r o g

1

L o c k

O n

T r i m

5 5

R a n g e

1 0

Side Panel

Parameter

Select

6

Advertising