NOTE: Lead holes for a #8 sheet metal screw have been provided in the sides
of the back box. After the finished wall or ceiling has been put up, drive a #8(m4)
sheet metal screw (recommended 1”(25mm) long) through the side of the box
not mounted to the stud.(joist) This will prevent the back from pulling out when
installing the heater assembly. (See Figure 1)

NOTE: Heaters are factory wired per nameplate, voltage and wattage. Refer to
Table1, page 3 for details. See “TO CHANGE WATTAGE OUTPUT” section if
lower wattage is desired and make change before installating heat deck.

INSTALLATION AND WIRING

OF HEATER / FAN ASSEMBLY

1.

Following wiring diagram (Figure 2) connect supply wires to heater lead-
wires in back box using appropriate wire connectors.

NOTE: For 120 volt heaters connect the white neutral supply lead to the heater’s white
or red with white flag marker pigtail lead, and connect the black supply lead to the black
pigtail lead.

2.

Secure supply ground wire under green ground screw in back box (or
green ground wire if provided).

3.

Fit heater/fan assembly into back box making sure all wiring is powitioned
away from fan and heating element.and secure in place with (2) screws
provided through the center slots in the sides of the fan assembly.

TO CHANGE WATTAGE OUTPUT

The chart below shows the wattages available by model. Each heater is facto-
ry wired for its maximum wattage. The last two columns in the chart refer to the
jumpers on the CLIP’n’FIT

®

Board. To change wattage, clip out jumper 1 and/or

jumper 2 as shown in the chart below. Completely remove jumpers by clipping
at both ends as close to the board as possible.

GENERAL

Wall Mounted

•The C series heaters are designed for recessed installation in 2 X 4 stud or
larger wall using the model CBB (Type CO2-BB) back box. The heater may
be wired using standard building (60 degrees C minimum) wire.

•The optimum mounting height for this heater is 18” to 24” (457mm to
610mm) from floor to bottom of back box. In any case, do not install closer
than 4.5” (114mm) from the floor or adjacent wall.

Ceiling Mount

•The C Series heaters are designed for ceiling mount provided the wattage
does not exceed 1000 watts. In order for your heater to be rated for
ceiling application, the heater must be trimmed back to 1000 watts or less.
(See Change Wattage Output below)
•The optimum clearances to any wall surface are 12 inches. Do not mount
heater in the ceiling if these clearances are not met.
•Ceiling heaters can be recessed or surfaced mounted.

Heaters are also approved for semi-recessed or surface mounting on walls. Refer to
instructions for installations of the CSM Surface Mounting frame.

INSTALLATION OF BACK BOX

IN NEW CONSTRUCTION

NOTE:

If the finished wall surface is already up, follow instructions for

“INSTALLATION OF BACK BOX IN EXISTING CONSTRUCTION”.

1.

Allow for the thickness of the finished surface when installing the back
box. The edge of the back box must be installed flush with the finished
surface. Markings on the side of the back box for 1/2” or 5/8” finishing
wall are provided.

2.

Determine which side of the back box is to be mounted against a stud or
joist and bend the tabs at the rear corners out 90 degrees so that the
back box will be square with the stud after installation.

3.

Remove one of the knockouts on left side of the back box and install a
cable or conduit connector. (See warning 13)

4.

Position back box against side with studs or ceiling joist and secure with
nails or screws as shown in Figure 1.

NOTE: The back box must be installed to a wall stud or ceiling joist and
secured using nails or screws as shown in Figure 1.

5.

Run power supply cable through the connector, leaving about 6” of wire
inside the box.

6.

Connect the supply cable ground wire to green ground wire provided.

NOTE: Lead holes for a #8 sheet metal screw have been provided in the sides
of the back box. After the finished wall or ceiling has been put up, drive a
#8(m4) sheet metal screw (recommended 1”(25mm) long) through the side of
the box not mounted to the stud. This will prevent the back box from pulling
out when installing the heater assembly. (See Figure1)

INSTALLATION OF BACK BOX

IN EXISTING CONSTRUCTION

1. The edge of the back box must be installed flush with the finished surface.

Determine which side of the back box is to be mounted against a stud or joist
and bend the tabs at the rear corners out 90 degrees so that the back
box will be square with the stud after installation.
(See Figure 1).

2. Carefully cut a hole measuring 9-3/8”(239mm) wide by 11-1/8”(284mm)

long. One edge of the hole must be cut along edge of the wall stud.

3. Bring power supply cable to heater mounting location leaving at least

10”(255mm) of cable for wiring.

4. Remove desired knockout on left side of back box.

5. Install cable clamp to cable and install into back box, leaving at least

6”(152mm) of cable in box for wiring.

6. Connect the supply cable ground wire to green ground wire provided.

7. Fit back box into mounting hole in wall by first inserting cable end of box then

rotating box into position.

8. Secure box to wall stud or ceiling joist using nails or screws.

2

Figure 1

BEND

OUT
TAB

CABLE CLAMP

LEAD

HOLES

BACK BOX

NAILS OR

SCREWS

SUPPLY
WIRING
CABLE

LAMP

R

M

ELEMENT

TCO

LIMIT
CONTROL

MOTOR

CLIP'N'FIT

®

2

1

3

RED

JUMPER

BLUE

JUMPER

REMOTE 1
POLE T'STAT

BLACK

RED

REMOTE OR
OPTIONAL 2
POLE T'STAT

BLACK

RED

L1

L2/N

Figure 2 Wiring Diagram

Figure 3 Clip’n’Fit

®

Board

WATTAGE

C1512IF

C2024IF

C2224IF

Jumper 1

Jumper 2

C1512T2

C1524T2

C2028IF

C2024T2

C2224T2

Blue

Red

@120V @208V @240V @208V

@208V @240V @208V @240V

Jumper

Jumper

1500

1125

1500

2000

1500

2000

1688

2250

Leave In Leave In

1125

844

1125

1500

1125

1500

1266

1688

Clip Out Leave In

750

563

750

1000

750

1000

844

1125

Leave In Clip Out

375

281

375

500

375

500

422

563

Clip Out Clip Out

TO PREVENT POSSIBLE WIRING DAMAGE CUT EXCESS SUPPLY
WIRE INSIDE BACKBOX TO PROVIDE APPROXIMATELY 6 INCHES
FOR CONNECTION TO HEATER LEADS. AFTER CONNECTIONS ARE
MADE, MAKE SURE CONNECTIONS ARE TIGHT AND ALL WIRING IS
POSITIONED AWAY FROM FAN BLADE AND HEATING ELEMENT.

CAUTION

!

Advertising