SECTION 4 − INSTALLATION

4-1. Specifications

Type of

Input

Power

Welding

Power

Source

Type

Wire Feed

Speed

Range

Wire

Diameter

Range

Input

Welding

Circuit

Rating

IP

Rating

Max. Wire

Spool

Capacity

Overall

Dimensions

Weight

Open-Circuit/

Arc Voltage,

14 − 110

Volts DC

Constant

Voltage (CV)

Or Constant

Current (CC)

DC Power

Source Only

50 − 780 ipm

(1.3 − 19.8

mpm)

Depending On

Arc Voltage

*Solid Steel:

.023 − .062 in

(0.6 − 1.6 mm);

Stainless Steel:

.023 − .052 in

(0.6 − 1.3 mm);

Flux Cored:

.030 − .062 in

(0.8 − 1.6 mm)

425 Amperes

At 60%

Duty Cycle

23

45 lb (20.4 kg),

12 in (304 mm)

Length: 21 in

(533 mm)

Width: 9 in

(229 mm)

Height: 15-1/2 in

(394 mm)

35 lb

(16 kg)

*Maximum gun length is 10 ft. for solid steel .062 in. wire.

4-2. Gun Recommendation Table

Process

Gun

GMAW − Hard or Corded Wires

Bernard Q - 4015

FCAW − Self-Shielding Wires

FC-1260

Dura-Flux

Notes