6. connecting shielding gas – Miller Electric 12VS User Manual
Page 21
OM-1500-19 Page 17
4-5. Connecting Welding Gun And Voltage Sensing Clamp
Ref. 804 002-C
!
Turn Off wire feeder and
welding power source. Stop
engine on welding
generator.
1
Gun Securing Knob
2
Gun Block
3
Gun Outlet Wire Guide
Loosen knob, insert gun end into
block. Position outlet wire guide as
close as possible to drive rolls with-
out touching. Tighten knob.
4
Gun Trigger Plug
5
Gun Trigger Receptacle
6
Voltage Sensing Clamp
Connect voltage sensing clamp to
workpiece.
1
2
3
4
5
Internal Side View
6
4-6. Connecting Shielding Gas
Ref. 804 003-A
1
Gas Hose With 5/8-18
Right-hand Thread Fittings
(Customer Supplied)
2
Shielding Gas Cylinder
.
Shielding gas pressure not to
exceed 100 psi (689 kPa).
3
Valve
4
Flowmeter
Close valve on cylinder when fin-
ished welding.
Tools Needed:
5/8 in
1
Rear View
2
3
4