3. equipment connection diagram – Miller Electric 12VS User Manual

Page 19

Advertising
background image

OM-1500-19 Page 15

4-3. Equipment Connection Diagram

Ref. 804 000-C

!

Turn Off wire feeder and

welding power source. Stop

engine on welding

generator.

!

Use only with CC/CV DC

Power Sources.

1

Constant Current (CC) or

Constant Voltage (CV)

Welding Power Supply

2

Weld Cable To Feeder

3

Ground Cable To Workpiece

Weld cable and ground cable con-

nections to power source (DCEN/

DCEP) are dependant on wire type.

.

Since feeder is not polarity sen-

sitive, there is no need for an

electrode polarity switch.

4

Workpiece

5

Voltage Sensing Clamp

Connect voltage sensing clamp to

workpiece.
6

Gun

7

Gun Trigger Receptacle

8

Wire Feeder

9

Gas Hose

10 Gas Cylinder
Use of shielding gas is dependant

on wire type.

.

Shielding gas pressure not to

exceed 100 psi (689 kPa).

1

2

3

4

8

9

10

6

7

5

Notes

Advertising