101487

Fan

IMPORTANT:

Remove fan

from motor shaft before
removing motor from heater.
The weight of the motor
resting on the fan could
damage the fan pitch.

1. Remove upper shell (see

page 10).

2. Use 1/8" allen wrench to

loosen setscrew which
holds fan to motor shaft.

3. Slip fan off motor shaft.
4. Clean fan using a soft cloth

moistened with kerosene or
solvent.

5. Dry fan thoroughly.
6. Replace fan on motor

shaft. Place fan hub flush
with end of motor shaft
(see Figure 18).

7. Place setscrew on flat of

shaft. Tighten setscrew
firmly (4.5-5.6 n-m/40-50
inch-pounds).

8. Replace fan guard and

upper shell.

Figure 15 - Gap Adjusting Screw Locations

Gap Adjusting
Screw

Gap
Adjusting
Screw

Blade

Rotor

.076/.101 mm
(.003"/.004") Gap
Measured With
Feeler Gauge

Fan

Motor
Shaft

Setscrew

Flush

Figure 18 - Fan Cross Section

Setscrew

Fan

Motor
Shaft

Figure 17 - Fan, Motor Shaft, and

Setscrew Location

Figure 16 - Sanding Rotor

Sandpaper

10. Install blades, pump plate,

air filters, and filter end
cover.

11. Replace fan guard and

upper shell.

12. Adjust pump pressure (see

page 12).

Note:

If rotor is still binding,

proceed as follows.

13. Perform steps 1 through 6,

page 13.

14. Place fine grade sandpaper

(600 grit) on flat surface.
Sand rotor lightly in
“figure 8” motion four
times (see Figure 16).

15. Reinstall insert and rotor.
16. Perform steps 10 through

12 above.