Trouble- shooting, Warning – Master Lock BH150CE User Manual

Page 9

Advertising
background image

9

101487

TROUBLE-

SHOOTING

WARNING

Never service heater while it is plugged in, operating, or hot.
Severe burns and electrical shock can occur.

OBSERVED FAULT

POSSIBLE CAUSE

REMEDY

Wrong pump pressure

Dirty air output, air intake,
and lint filters

Dirty fuel filter

Dirt in nozzle

Dirty photocell lens

Bad flame-out control

Heater ignites, but
flame-out control
shuts off heater after
a short period of
time.

See Pump Pressure

Adjustment, page 12.

See Air Output, Air Intake

and Lint Filters, page 11.

See Fuel Filter, page 10.

See Nozzle, page 12.

Clean photocell lens.

Replace flame-out control.

Heater will not
ignite, but motor runs
for a short period of
time.

Wrong pump pressure

Carbon deposits on spark

plug and/or improper gap

Dirty fuel filter

Dirt in nozzle

Water in fuel tank

Electronic ignitor not

grounded (earthed)

Bad electronic ignitor

See Pump Pressure

Adjustment, page 12.

See Spark Plug, page 11.

See Fuel Filter, page 10.

See Nozzle, page 12.

Drain and flush fuel tank

with clean kerosene. See
Storage, page 8.

Make sure electronic

ignitor mounting is tight.

Replace electronic

ignitor.

Reset flame-out control

button, see Figure 4,
page 7.

If fan is hard to turn, see

Pump Rotor, page 13.

WARNING: High voltage!

Flame-out control not reset

Binding pump rotor

Motor does not start
when heater is
plugged in, fan
rotates slowly or
does not turn.

Advertising