5. connecting spool gun to renegade 180 – Miller Electric OM-234 016D User Manual

Page 24

Advertising
background image

OM-234 016 Page 15

3-5. Connecting Spool Gun To Renegade 180

804 755-B

1

Drive Assembly

2

Spool Gun

3

Gun Securing Knob

4

Gun End

Loosen gun securing knob. Insert

end through opening until it bottoms

against drive assembly. Tighten

gun securing knob.

.

Be sure that gun end is tight
against drive assembly. Ex-

posed O−rings will cause

shielding gas leakage.

Spool gun must be inserted

completely to prevent leakage of

shielding gas.
5

Gun Trigger Plug

Insert plug into receptacle, and

tighten threaded collar.
6

Spool Gun/MIG Gun Switch

Place switch in Spool Gun position.
7

Polarity Changeover Terminal

Block

To make proper polarity connection,

see welding power source Owner’s

Manual. Typically, DCEP is used for

solid and aluminum wire.
Close door.

6

5

7

1

3

2

4