ERRATA SHEET

2009−02

OM-234 016D

Use above FORM number when ordering extra manuals.

After this manual was printed, refinements in equipment design occurred. This sheet lists exceptions to data

appearing later in this manual.

CHANGES TO SECTION 3 − INSTALLATION

Add Section 3-7.

Connecting Spool Gun To Millermatic 211 Auto-Sett

Ref. 804 984-A / Ref. 805 390-A / Ref. 801 987

1

Drive Assembly

2

Spool Gun

3

Gun Securing Knob

4

Gun End

Loosen thumbscrew. Insert end through

opening until it bottoms against drive

assembly. Tighten gun securing knob.
Spool gun must be inserted completely to

prevent leakage of shielding gas.
5

Gun Trigger Plug

Insert plug into receptacle, and tighten

threaded collar.

6

Polarity Changeover Terminal Block

To make proper polarity connection, see

welding power source Owner’s Manual.
7

MIG Gun/Spool Gun Switch

Place switch in Spool Gun position.

Close door.

Incorrect

Gun Fully Seated

Gun Not Seated

Correct

.

Be sure that gun end is tight against drive assembly.

4

4

Exposed O-rings

will cause shielding

gas leakage.

5

6

1

3

2

4

7