MPI Technologies FCX User Manual

Page 6

Advertising
background image

  

,1752'8&7,21

  352'8&7 67$1'$5' 5$7,1*6

Ratings for Model FCX are provided in the following
table:

Ratings are for the boiler when connected to stan-
dard option coaxial flue system components.

  ',$0(7(5 2) 3,3( &211(&7,216

3HUIRUPDQFH 3DUDPHWHU

8QLWV

3URGXFW 5DWLQJ

Rated Output

BTUH

76,000

Rated Input

BTUH

81,250

Combustion Chamber Length

Inches

8.98

Combustion Chamber Diameter

Inches

11.5

Combustion Chamber Volume

Cu. Inches

915

Combustion Prod. Circuit Volume

Cu. Inches

3051

Flue Pressure Drop

Inches H2O

0.10

Maximum Heating Service Pressure

Psig

43.5

Max Heating circuit water temperature

Deg. F

176

Water Overheating Safety Thermostat Setting

Deg. F

230

Combustion Prod. Overheating Safety Thermostat Setting

Deg. F

248

Heating Circuit Water Capacity

Gallons

4.23

Primary Water Flow Rate (60/80 deg. C)

Gal/hr

254

Water Pressure Drop (at nominal flow rate)

MCE

1.4

Power Absorbed (with burner, without circulator)

KW

0.22

Packaged Weight

Lb.

267

Electrical Power Supply

115 volts, single phase, 60 Hz

Full Load Current

3.0 Amps FLA

Max Fuse/ Circuit Breaker Size

15 Amps

&RQQHFWLRQ

'LDPHWHU

8QLWV

Combustion Products

3.15 / 4.92

Inch

Water Heating Supply/Return

1

Inch

Domestic Hot Water or Second Heating Circuit

1

Inch

Condensate Drain

1 -1/2

Inch

Heating Water Drain

½

Inch

Air Bleed

3/8

Inch

Safety pressure relief valve

3/4

inch

Advertising