CABLE SPECIFICATIONS

Fiber Cable

Bit error rate:

10-9

MULTIMODE

Fiber Optic Cable Recommended:

62.5 / 125 µm multimode fiber

Optional:

100 / 140 µm multimode fiber
85 / 125 µm multimode fiber
50 / 125 µm multimode fiber

T1E1-CF-01

850 nM

Fiber Optic Transmitter Power:

min: -14.0 dBm

max: -12.0 dBm

Fiber Optic Receiver Sensitivity:

min: -25.0 dBm

max: -12.0 dBm

Typical Maximum Cable Distance*:

2 kilometers

T1E1-CF-01(SC)

850 nM

Fiber-optic Transmitter Power:

min: -14.0 dBm

max: -12.0 dBm

Fiber-optic Receiver Sensitivity:

min: -25.0 dBm

max: -12.0 dBm

Typical Maximum Cable Distance*:

2 kilometers

SINGLEMODE

Fiber Optic Cable Recommended:

9 µm singlemode fiber

T1E1-CF-01(SM)

1300 nM

Fiber-optic Transmitter Power:

min: -21.0 dBm

max: -14.0 dBm

Fiber-optic Receiver Sensitivity:

min: -25.0 dBm

max: -14.0 dBm

Typical Maximum Cable Distance*:

8 kilometers

T1E1-CF-01(LH)

1300 nM

Fiber-optic Transmitter Power:

min: -15.0 dBm

max: -5.0 dBm

Fiber-optic Receiver Sensitivity:

min: -25.0 dBm

max: -14.0 dBm

Typical Maximum Cable Distance*:

15 kilometers

*Actual distance dependent upon physical characteristics of network installation.

Twisted-Pair Copper Cable

Twisted pair connection requires two active pairs. The two active pairs in a T1/E1
network are pins 1 & 2 and pins 4 & 5. Use only dedicated wire pairs (such as
blue/white & white/blue) for the active pins.

Category 3 or better twisted-pair copper wire is required. Either shielded twisted-
pair (STP) or unshielded twisted-pair (UTP) can be used.

T1:

Gauge

24 to 22 AWG

Attenuation

2.6 dB/100 meters @ 1.0 MHz

Differential Characteristic Impedance

100

±10%

E1:

Gauge

24 to 22 AWG

Attenuation

2.6 dB/100 meters @ 1.0 MHz

Differential Characteristic Impedance

120

±10%

Coax Copper Cable

E1:

Gauge

24 to 22 AWG

Attenuation

2 dB/100 meters @ 1.0 MHz

Differential Characteristic Impedance

75

±10%

å

Dry-Contact Relay

RJ-45 dry-contact relay opens if power, signal detect/copper or signal
detect/fiber are lost.

Operational rating on pins 3 and 6: 0-30VDC maximum 1A

Switch-Selectable Configurations

T1 COPPER RJ-45

Configured as either "long haul" or “short haul” on 100 ohm cable, with
a variety of selectable distance settings.

E1 COPPER RJ-45

Configured as either "long haul" or “short haul” on 120 ohm cable.

E1 COPPER COAX

Configured as either "long haul" or “short haul” on 75 ohm cable.

STRAIGHT-THROUGH/CROSSOVER RJ-45

Allows straight-through cable to be used where crossover-configuration
cable is required.

Switch-Selectable Functions

LOOPBACK TEST FUNCTION

A loopback switch facilitates installation and network debug procedures.
The path for the T1E1-CF-01 loopback is shown:

TRANSMIT ALL ONES FUNCTION

A selectable Transmit All Ones switch on the fiber interface and on the
twisted-pair interface allows for insertion of an “all ones” pattern on that
interface when signal detect is lost, which creates an alarm condition at
the equipment connected to the interface.

Fiber

TP

TP

RJ-45

Relay

3

6

Advertising