Installation, Set switches – Milan Technology T1E1-CF-01 User Manual

Page 4

Advertising
background image

INSTALLATION

Set Switches

Use small flatblade screwdriver or
similar device to set recessed
switches for site installation. Refer
to label on top of media converter
for MDI/ MDI-X switch settings.
Refer to drawings below and at right
for four-position switch settings.

5.

Is the AISTP LED on either media converter illuminated?
YES

Determine and correct failure of remote unit connected to twisted-
pair interface that caused All Ones Insertion (AIS) on the twisted-

pair interface.

NO

Contact Technical Support: (800) 260-1312/(800) LAN-WANS.

SHORT HAUL Switch Settings

Switch #4 UP

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

1

2

E1 2.37V

75 ohm cable

Coax connectors

E1 3.0V

120 ohm cable

RJ-45 connector

DSX-1 0'-133'

100 ohm cable

DSX-1 133'-266'

100 ohm cable

DSX-1 266'-399'

100 ohm cable

DSX-1 399'-533'

100 ohm cable

DSX-1 533'-655'

100 ohm cable

ANSI T1.403

100 ohm cable

DSX-1 6.0V

100 ohm cable

1 2 3 4

*LONG HAUL Switch Settings

Switch #4 DOWN

1 2 3 4

1

2

1

2

1

2

1

2

0 db

-22.5 db

-15 db

-7.5 db

*Switch #3 not used

for long haul settings.

1 2 3 4

5 6 7 8

KEY

= UP

= DOWN

Fiber

TP

TP

AISTP

Advertising