Fault isolation and correction – Milan Technology T1E1-CF-01 User Manual

Page 5

Advertising
background image

FAULT ISOLATION and CORRECTION

If the media converter fails, isolate and correct the failure by determining the
answers to the following questions and then taking the indicated action:

1.

Is the Power LED on the media converter illuminated?
NO

Is the power adapter the proper voltage and cycle frequency for the
AC outlet?
NOTE: Refer to the “Power Supply Requirements” on page 7.

Is the power adapter properly installed in the media converter and
in the outlet?

Contact Technical Support: (800) 260-1312/(800) LAN-WANS.

YES

Proceed to step 2.

2.

Is the SDFiber (Signal Detect/Fiber) LED illuminated?
NO

Check fiber cables for proper connection.

Verify that TX and RX cables on media converter are connected to
RX and TX ports, respectively, on other media converter.

Contact Technical Support: (800) 260-1312/(800) LAN-WANS.

YES

Proceed to step 3.

3.

Is the SDTP (Signal Detect/Twisted-Pair) LED illuminated?
NO

Check twisted pair cables for proper connection.

Check RJ-45 Pinning Switch for correct twisted pair cable
configuration.

Check integrity of device attached to media converter by twisted-
pair cable.

Contact Technical Support: (800) 260-1312/(800) LAN-WANS.

YES

Proceed to step 4.

4.

Is the AISFiber LED on either media converter illuminated?
NO

Proceed to step 5.

YES

Determine if broken fiber link has caused All Ones Insertion (AIS)
on the fiber interface and correct failure. If not, proceed to step 5.

Set switches 5, 6, and 7 to
enable test functions or to
permit normal network
operation. (Switch 8 not used.)

Set the MDI/MDI-X switch to use straight-through cable where crossover-
configuration cable is required.

1

2

1

2

1

2

1

2

1

2

1

2

Loop Transmit TP

to Receive TP

NO Transmit All Ones

onto Fiber

Transmit All Ones onto

Fiber on loss of SDFiber

Normal Operation

NO Transmit All Ones

onto Twisted-Pair

Transmit All Ones onto

TP on loss of SDTP

5 6 7 8

*NETWORK Switch Settings

*Switch #8 not used.

1 2 3 4

5 6 7 8

Twisted
Pair #1

Twisted
Pair #2

1

2

4

5

RTIP

TTIP

RRING

TRING

TTIP

RTIP

TRING

RRING

RTIP

TTIP

RRING

TRING

RTIP

TTIP

RRING

TRING

Twisted
Pair #1

Twisted
Pair #2

1

2

4

5

MDI

MDI-X

Connectors for unlike devices

Connectors for like devices

KEY

= UP

= DOWN

Fiber

TP

TP

AISFiber

Advertising