Maxtor 1925 User Manual

Page 45

Advertising
background image

ATA Bus Interface and ATA Commands

5-2

Quickview 40 20/30/40GB AT

5.4

REGISTER ADDRESS DECODING

The Maxtor Quickview 40 hard disk drives allow their host systems to address the full
set of command and control registers as specified in clause 7 of the ATA/ATAPI-6
standard.

5.5

COMMAND INTERFACE

5.5.1

General Feature Set

The µProcessor, Disk Controller, and ATA Interface electronics are contained in a
proprietary ASIC developed by Maxtor.

5.5.2

Supported Commands

The Maxtor Quickview 40 hard disk drives support all the mandatory commands from
the general feature set for devices not supporting the Packet command feature set.
Refer to the ATA/ATAPI-6 standard for a detailed description of these commands.
The IDENTIFY DRIVE command, however, is elaborated in the section "Identify
Drive Command" on page 5-
5.

Table 5-1 lists the supported commands.

Table 5-1

Supported Commands

Command

Command

Code

Feature

Register

Value(s)

CHECK POWER MODE

98h, E5h

DEVICE CONFIGURATION FREEZE LOCK

B1h

C1h

DEVICE CONFIGURATION IDENTIFY

B1h

C2h

DEVICE CONFIGURATION RESTORE

B1h

C0h

DEVICE CONFIGURATION SET

B1h

C3h

DOWNLOAD MICROCODE

92h

07h, 01h

EXECUTE DRIVE DIAGNOSTIC

90h

FLUSH CACHE

E7h

IDENTIFY DRIVE

ECh

IDLE

97h, E3h

IDLE IMMEDIATE

95h, E1h

NOP

00h

Advertising