Using the attachments, Using & cleaning the turbo nozzle, Using the stair and hair tool – Morphy Richards 73332 User Manual

Page 5: Emptying

Advertising
background image

55

Using the

attachments

Follow steps 1-4 but set the

carpet height adjustment knob

to the TOOLS setting.

5

Remove the hose connector Í

from the rear of the cleaner. Lift

the hose · from the top handle

hook. Insert the hose clip Ò

into the hose clip slot Ë.

Push the required attachment

firmly onto the end of the hose.

If additional length is required,

attach one or both extension

tubes Â.

6

Switch on „.

IMPORTANT: Always fix the

hose clip Ò to the main body

slot Ë when using the hose and

tools.

Never over extend the hose

such that the cleaner is pulled

over.

IMPORTANT: Turning the cleaner

sideways helps prevent the

cleaner being pulled along by

the stretch hose.

Using & cleaning the

turbo nozzle

(Certain models only)
Attach the turbo nozzle Ú to

the hose end connector Í.

Following use, your turbo nozzle

may become clogged. Turn over

the nozzle and pull away any

hairs or fibres. If they are tightly

wound around the brush,

carefully snip the fibres with

scissors, being careful not to

damage the brush bar, pull away

from the brush bar and dispose.

Using the Stair and

Hair tool

(Certain models only)

Attach the stair tool Û to the

hose connector Í for effective

stair cleaning.

Attach the hair tool Ù to the

stair tool for fantastic pet and

human hair pick-up D.

EMPTYING

Empty the dust canister

regularly even if it does not look

full, this will maintain the

performance.

1

Remove the front cover ‹ by

lifting the cover release lever ¤

E

.

2

Lift-up the dust canister release

Î

and pull the canister away

from the main body.

3

Take the canister to the dustbin.

4

Turn the lid quarter-of-a-turn

anti-clockwise to unlock, lift off

the lid with pleated filter Ì, put

to one side F.

5

Lift out the central mesh filter Ô

from the dust canister Ó G.

Brush clean if necessary.

6

Empty out the dust canister Ó.

7

Re-fit the central mesh filter.

8

Shake the pleated filter Ì to

remove all dust.

9

Re-fit pleated filter with lid into

the dust canister by lining up the

two arrows and turning the lid

quarter-of-a-turn clockwise to

lock.

10

Re-fit dust canister into cleaner

and push to lock into position.

11

Re-fit the front cover.

E

F