2-22

SECTION 2

INSTALLATION

6

6

4

5

2

2

3

3

1

5

GAS OVEN ROUGH-IN

UTILITY ROUGH-IN DIMENSIONS AND POSITIONING

GAS SUPPLY

&

ELECTRICAL SUPPLY

PROVIDED BY CUSTOMER

DO NOT USE CONDUIT

FOR GROUND

CIRCUIT BREAKER

1 circuit breaker/fused disconnect switch with

lockout/tagout is required for each oven

cavity. Wire each oven cavity separately.

ELECTRICAL SPECIFICATIONS

220-230V, 1 Ph, 8 Amp draw, 50 Hz, 2 pole, 3

wire system per oven cavity (2 hot, 1 grd).

GAS RATING

Models PS360U/L: 135,000 BTU/HR,

34,020kcal/HR, 40kW/HR

Models PS360WB-U/-L: 170,000 BTU/HR,

42,840kcal/HR, 50kW/HR

MINIMUM GAS METER RATING

600 Ft.

3

/Hour (17m

3

h) for 1 or 2 oven cavities.

1200 Ft.

3

/Hour (34m

3

h) for 3 or 4 oven cavities.

Minimum rating does not take other gas

appliances into consideration. Gas

consumption varies at each site. Total

BTU/HR (kcal/hr) must be calculated on high

flame off of each appliance to determine if

meter needs to be larger.

MINIMUM GAS PIPE SIZE

Natural: 2" (51mm) ID for 1 or 2 oven cavities

with runs up to 200 ft.(61m).

OR

2-1/2" (64mm) ID for 3 or 4 oven cavities with

runs up to 200 ft.(61m)

Must be a dedicated line.

Runs over 200 ft. consult factory
Propane:
1-1/2" (38mm) ID for 1 or 2 oven

cavities with runs up to 200 ft.(61m).

OR

2" (51mm) ID for 3 or 4 oven cavities with runs

up to 200 ft.(61m).

Must be a dedicated line.

Runs over 200 ft. consult factory

Figure 2-31

Oven Rough-In

CAUTION

IT IS REQUIRED THAT THE OVEN BE

PLACED UNDER A VENTILATION

HOOD FOR ADEQUATE AIR SUPPLY

AND VENTILATION.

To

Oven

GAS VALVES

3/4" (19mm) ID full flow gas shut-off valve.

A separate connection and valve must be provided for each oven.

REQUIRED SUPPLY GAS PRESSURE

Natural: 20-30mbar

Propane: 50mbar

SUGGESTED

If space permits, service should be located to the left of the ovens to

allow access to switches and valves.

User Supplied Items:
ITEM

DESCRIPTION

1

2"(51mm) X 2"(51mm) X 3/4"(19mm) TEE

2

3/4"(19mm) X 3"(76mm) NIPPLE

3

3/4" (19mm)FULLFLOW GAS SHUT-OFF VALVE

4

2"(51mm) X 3/4"(19mm) 90° REDUCER ELBOW

5

2"(51mm) ID GAS SUPPLY PIPE LINE-NATURAL GAS

6

15 AMP TOGGLE SWITCH - 2 POLE for GAS

To

Oven

To

Oven

To

Oven