background image

3-9

SECTION 3

OPERATION

Figure 3-11

Middleby Marshall

ALM

HEAT

92

FAIL SF

2

C

c.

FAILSF (Failsafe) See Figure 3-11.

AA. If the oven does not reach 200°F (93°C) in 15
minutes, the temperature controller will shut off the
high flame valve and begin flashing “FAILSF” and
“SET PT” alternately. You will also note that the “2”
in the ALM window stays on. This condition signals
a problem in oven heating or heat sensing.

BB. To reset the temperature controller, turn off the

blower switch

. Wait 10 seconds and turn the

blower switch

back on. The “2” in the ALM

window, the current temperature set point, and the
words “SET PT” will be displayed again. The tem-
perature controller will now cycle through its normal
procedures.

d. F/C - The F/C window will display either an “F” or a

“C”.

AA. The “F” indicates that the temperature displayed
is in degrees Fahrenheit.

BB. The “C” indicates that the temperature displayed
is in degrees Celsius.

Advertising