15

Majestic Fireplaces

®

BR/BC Series

7412944

MA81

rev. 8/5/97

1¹⁄₂"

Ref.

Combustible materials are

permitted within a shaded area

shown in Figure 23 titled

Minimum Wall Clearances.

*

**

MA81

Fig. 22 Combustible mantel clearances.

*12" from top of fireplace opening for radiant models
12" from top of grille opening for circulating models
**6" from top of fireplace opening for radiant models
(Noncombustible material must seperate the black
face surround of the fireplace from any combustible
mantel material)
6" from top of grille opening for circulating models

Face Plate

12"

(305mm)

Max.

FP531a

BR/BC

mantel clearances

9/03 djt

���

"

12"

(305mm)

Max.

12"

(305mm)

Min.

1���"

(38mm)

*

12"

(305mm)

Min.

1���"

(38mm)

6"

(159mm)

Min.

12"

(305mm)

Max.

12"

(305mm)

Min.

1���"

(38mm)

6"

(159mm)

Min.

Mantel Clearance - Radiant Model - No
Noncombustible Facing Material

Combustible

Mantel and

Trim

Finished

Wall

Header

Standoff

Noncombustible

Material

Radiant

Surround

Face

Fireplace Opening

* Minimum width from top of sur-
round to bottom of screen rail

Combustible

Mantel and

Trim

Finished Wall

Header

Standoff

Noncombustible

Material

Radiant

Surround

Face

Fireplace Opening

Mantel Clearance - Radiant
Model - with Noncombustible
Facing Material

Combustible

Mantel and

Trim

Finished Wall

Header

Standoff

Noncombustible

Material

Circulating

Surround

Face

Fireplace Opening

Noncombustible

Facing Material

Mantel Clearance -
Circulating Model

2 x 4 Stud

Finished Wall

Must be sealed with non-

combustible material

Fireplace Front

Top View

FP531a

Fig. 21 Mantel clearances.