OM-4406 Page 35

Return To Table Of Contents

7-2. Description Of Front Panel Controls For CC/CV Models (See Section 7-1)

Engine Starting Controls
1

Magnetic Shutdown Switch

Use switch during start-up to bypass engine

shutdown system. System stops engine if oil

pressure is too low or engine temperature is

too high.
2

Starting Aid Switch

Use switch to energize starting aid for cold

weather starting (see starting instructions fol-

lowing).
3

Engine Control Switch

Use switch to start engine, select engine

speed ( if unit has auto idle option), and stop

engine.
In Run position, engine runs at weld/power

speed. In Run/Idle position (optional), engine

runs at idle speed at no load and weld speed

with load applied.
To Start:
Y Do not use ether.

.

If engine does not start, let engine come
to a complete stop before attempting re-

start.

Above 325 F (05 C): turn Engine Control

switch to Start while pressing Shutdown

switch. Release Engine Control switch when

engine starts. Continue holding Shutdown

switch until engine indicator lights go out.
Below 325 F (05 C): turn engine control switch

to Run/Idle position. Push Starting Aid switch

up for 60 seconds. While still holding Starting

Aid switch, press Magnetic Shutdown switch

and turn Engine Control switch to Start. Re-

lease Engine Control switch and Starting Aid

switch when engine starts. Continue holding

Shutdown switch until engine indicator lights

go out.
To Stop: turn Engine Control switch to Off

position.
Engine Indicator Lights
4

Battery Charging Light

Light goes on if engine alternator is not charg-

ing battery. Engine continues to run.
Y Stop engine and fix trouble if Battery

Charging light goes on.

5

Engine Temperature Light

Light goes on and engine stops if engine tem-

perature is above 221

°

F (105

°

C).

Y Stop engine and fix trouble if Engine

Temperature light goes on.

6

Engine Oil Pressure Light

Light goes on and engine stops if oil pressure

is below 5 psi (34 kPa). Light goes on momen-

tarily during start-up but goes out when en-

gine reaches normal oil pressure.
Y Stop engine and fix trouble if Engine

Oil Pressure light stays on after start-

up.

7

Fuel Light

Light is not active on this model.
8

Engine Hour Meter

Engine Gauges

.

To read gauges and engine indicator

lights with engine off, turn Engine Control

switch to Run/Idle and press Magnetic

Shutdown switch (see Section 9-9).

9

Fuel Gauge

Use gauge to check fuel level.
To check fuel level when engine is not run-

ning, turn Engine Control switch to Run/Idle

position and press Magnetic Shutdown

switch.
10 Battery Voltmeter (Optional)
Use gauge to check battery voltage and moni-

tor the engine charging system. The meter

should read about 14 volts dc when the en-

gine is running, and about 12 volts dc when

the engine is stopped.
11 Engine Coolant Temperature Gauge

(Optional)

Normal temperature is 180 - 203

°

F (82 - 95

°

C). When equipped with gauge option, engine

stops if temperature exceeds 220

°

F (104

°

C).

12 Engine Oil Pressure Gauge (Optional)
Normal pressure is 30 − 60 psi (207 − 414

kPa). When equipped with gauge option, en-

gine stops if pressure is below 10 psi (69

kPa).
Weld Controls
13 Process/Contactor Switch
See Section 7-3 for Process/Contactor

switch information.
14 Ampere Range Switch
Y Do not switch under load.
Use switch to select weld amperage range.
Use the lowest four ranges for Stick and TIG

welding. Read the upper set of numbers at

each range for Stick welding and the lower set

at each range for TIG welding.
Use the highest range for MIG welding and for

cutting and gouging (CAC-A).
For most welding applications, use lowest

amperage range possible to help prevent arc

outages.

15 Voltage/Amperage Adjust Control
With Process/Contactor switch in any Stick or

TIG setting, use control to adjust amperage

within range selected by Ampere Range

switch. With Process/Contactor switch in any

MIG position, use control to adjust voltage.

With Voltage/Amperage Adjust Switch in Re-

mote position, control limits the remote am-

perage in TIG mode, but has no effect in Stick

and MIG modes.
Weld output would be about 213 A DC with

controls set as shown (50% of 110 to 315 A).

.

The numbers around the control are for
reference only and do not represent an

actual percentage value.

16 Voltage/Amperage Adjust Switch And

Remote 14 Receptacle

Use switch to select front panel or remote

voltage/amperage control. For remote con-

trol, place switch in Remote position and con-

nect remote control to Remote 14 receptacle

RC14 (see Sections 5-11 and 7-4).
17 Polarity Switch (Optional)
Y Do not switch under load.
Use the Polarity switch to change weld out-

put. Select either DC Electrode Positive

(DCEP) or DC Electrode Negative (DCEN).
18 Polarity/AC Switch (Optional)
Y Electric shock can kill.
Y Do not use AC output in damp areas,

if movement is confined, or if there is

a danger of falling.

Y Use AC output ONLY if required for the

welding process. If AC output is re-

quired, use remote output control if

present on unit.

Y Do not switch under load.
Use Polarity/AC switch to select AC or DC

weld output and DC weld output polarity. For

Direct Current Electrode Negative (DCEN),

turn switch to − (Negative) position. For Direct

Current Electrode Positive (DCEP), turn

switch to + (Positive) position. For weld pro-

cesses that require alternating current (AC),

use AC position.
Weld Meters

.

Optional weld meters do not work with

optional Polarity/AC switch in AC

position.

19 DC Voltmeter (Optional)
Voltmeter displays voltage at the weld output

terminals, but not necessarily the welding arc

due to resistance of cable and connections.
20 DC Ammeter (Optional)
Ammeter displays amperage output of the

unit.