Miller Electric Big 40 CAT User Manual

Page 59

Advertising
background image

OM-4406 Page 53

Return To Table Of Contents

Trouble

Remedy

Engine cranks but does not start.

Press Magnetic Shutdown switch MS1 when starting engine.

Check fuel level.

Reset circuit breaker CB13 (see Section 9-8). Have Factory Authorized Service Agent check engine-

wiring harness and components.

Check battery and replace if necessary. Check engine charging system according to engine manual.

Have Factory Authorized Service Agent check control relay CR2, and fuel solenoid FS1.

Air in fuel system. See engine manual.

Engine starts, but stops when Magnetic

Shutdown switch is released.

When starting engine, continue holding Magnetic Shutdown switch until after engine indicator lights go

out.

Check oil, and coolant levels. Automatic shutdown system stops engine if oil pressure is too low or coolant

temperature is too high (see Sections 5-7 and 9-9).

Engine hard to start in cold weather.

Use starting aid switch (see Section 6-1 or 7-1).

Keep battery in good condition. Store battery in warm area off cold surface.

Use fuel formulated for cold weather (diesel fuel can gel in cold weather). Contact local fuel supplier for

fuel information.

Use correct grade oil for cold weather (see Section 9-1).

Engine suddenly stops.

Check oil and coolant levels. Automatic shutdown system stops engine if oil pressure is too low or coolant

temperature is too high (see Sections 5-7 and 9-9).

See engine manual.

Engine slowly stopped and cannot be

restarted.

Check fuel level.

Check engine air and fuel filters (see Sections 9-4 and 9-7).

See engine manual.

Battery discharges between uses.

Turn Engine Control switch off when unit is not running.

Clean top of battery with baking soda and water solution; rinse with clear water.

Recharge or replace battery if necessary.

Periodically recharge battery (approximately every 3 months).

Engine idles, but does not come up to

weld speed.

Have Factory Authorized Service Agent check idle module PC7 and current transformer CT1.

Check for obstructed throttle solenoid.

Engine does not run at idle speed.

CC models: place Stick/TIG Selection switch in Stick position.

CC/CV models: place Process/Contactor switch in any position but Remote-TIG.

Check for obstructed throttle solenoid.

Have Factory Authorized Service Agent check idle module PC7, and control relays CR3 and CR6.

Engine uses oil during run-in period;

wetstacking occurs.

Dry engine according to run-in procedure (see Section 11).