Design specifications, Operational – Metrologic Instruments MS9500 Voyager User Manual

Page 37

Advertising
background image

31

D

ESIGN

S

PECIFICATIONS

MS9500 Series Specifications

O

PERATIONAL

Light Source

Visible Laser Diode 650 nm

Laser Power:

Less than 1 mW (peak)

Depth of Scan Field:

0 mm - 203 mm (0" - 8") for
0.330 mm (13 mil) bar code@ default setting

Scan Speed:

72 scan lines per second

Scan Pattern:

Single scan line

Minimum Bar Width:

0.127 mm (5.0 mil)

Infrared Activation:

Long Range: 0 mm – 279 mm ± 51 mm (0" – 11" ± 2")
Short Range: 0 mm – 102 mm ± 25 mm (0" – 4" ± 1")

Decode Capability

Autodiscriminates all standard bar codes for others call
a Metrologic service representative

System Interfaces

RS232, PC Keyboard Wedge, Stand-Alone Keyboard,
OCIA, IBM 468X/469X, Light Pen Emulation, Laser
Emulation, RS232 with DSR, Low Speed USB POS or
HID, Full Speed USB

Print Contrast:

35% minimum reflectance difference

Number Characters

Read:

Up to 80 data characters (Maximum number will vary
based on symbology & density
)

Roll, Pitch, Yaw:

42°, 68°, 52°

Beeper Operation:

7 tones or no beep

Green* LED = laser on, ready to scan

Red* LED = good read

Visual Indicators:

Default Settings

Yellow LED (MS9540 Only) =
ON, CodeGate button is inactive
OFF, CodeGate button is active

*

In some custom units the standard green LED has been replaced with a blue LED
and the red LED has been replaced with a white LED.

Specifications subject to change without notice.
.

Advertising