Alarms

Alarms are activated by status changes in network devices. When MegaVision detects a
change in a device, it generates an alarm. A beep is sounded and the alarm is recorded in the
Alarm Log, indicating the date and time, the device in which it occurred, the severity, and a
short description of the reason for the alarm. An alarm is also reflected in the device icon—
the icon color changes according to the severity of the alarm. Alarms have four severity
levels, each represented by a different color: Critical, Warning, Normal, and Informational.
Please note that a lot of alarms are actually generated by SNMP Traps, which are sent by
different network devices.

Alarm Notifications

In addition to an audible sound notifying you of an alarm condition, the color of a device icon
corresponds to the latest alarm with the highest severity. When an event received cancels
any previously received alarm, and the color of the icon is updated to reflect the new status of
the device.

Alarm Severity

Color

Informational

Purple

Normal

Green

Critical

Red

Unknown

Gray

Alarm notifications may be received via e-Mail as well (see below).

Viewing the Alarm Messages
Choose the Monitor/Alarm Log item from the Main Window menu. The Alarm Log window